To Set the Video Reference Type
All audio/video outputs from the system will be locked to the reference source.
1.
From the Main Menu, use the
SELECT
knob to select
Options Menu
and press the
SET
knob.
2.
Use the
SELECT
knob to select
Genlock
.
3.
Use the
SET
knob to select the reference type you want to use.
•
Free Run
— audio/video outputs are not locked to any reference signal.
•
PGM Video IN
— audio/video outputs are locked to the SDI video signal present on the PGM IN
BNC.
•
AUX Video IN
— audio/video outputs are locked to the SDI video signal present on the AUX IN
BNC.
•
Bi-Lvl REF IN
— audio/video outputs are locked to the Bi-Level sync analog video signal present
on the REF IN BNC.
•
Tri-Lvl REF IN
— audio/video outputs are locked to the Tri-Level sync analog video signal present
on the REF IN BNC.
4.
Use the
SELECT
knob to select
Save Changes
and press the
SET
knob to select
OK
.
To Adjust Video Timing
You can adjust the timing of the output video for both the PGM OUT and TAP OUT.
1.
From the Main Menu, use the
SELECT
knob to select
Options Menu
and press the
SET
knob.
2.
Use the
SELECT
knob to select
H OUT Timing
.
3.
Use the
SET
knob to adjust the horizontal position of the PGM OUT and TAP OUT SDI video signals,
in pixels, relative to the reference source. (0 to max)
4.
Use the
SELECT
knob to select
V OUT Timing
.
5.
Use the
SET
knob to adjust the vertical position of the PGM OUT and TAP OUT SDI video signals, in
lines, relative to the reference source. (-10 to 10)
6.
Use the
SELECT
knob to select
Pix Vert. Shift
.
7.
Use the
SET
knob to adjust the vertical picture position of the PGM OUT and TAP OUT SDI video
signals relative to the reference source. (0 to 50)
8.
Use the
SELECT
knob to select
Save Changes
and press the
SET
knob to select
OK
.
22 • Video Reference — AirCleaner-2 User Manual (v01)