13 • Configuration (Iss. 05)
Configuration
Use the
Function Select
switch and the
Down
and
Up
buttons to configure
the ADR-9039 to convert analog video signals to SDI. Settings are described in
the section “
Function Setup and Configuration Menus
” on page 14. Refer to
for switch and button locations.
Figure 7
ADR-9039 Switch and Button Locations
General Operating Rules
Please note the following important operating rules for the ADR-9039:
•
For each of the supported Reference Standard (525/625), the
ADR-9039 stores the timing settings independently in non-volatile
memory.
•
The ADR-9039 always powers up in the last configuration used.
•
Always check to see that the
OK
LED is lit. If not, check that the input
is valid and the correct Reference Standard has been selected from the
Function
menu.
Example Configuration
1.
To configure the Reference Standard function:
•
Turn the
Function Select
switch to Position
6
. The default
configuration is Auto Select.
•
Both LEDs are now lit, to indicate this configuration selection.
2.
To change Reference Standard configuration to PAL (625):
•
Keep the
Function Select
in Position
6
.
•
Press the
Up
button twice.
•
The
DOWN
LED will be unlit and the
UP
LED will be lit, to
indicate PAL (625) configuration selection.
Down Button
Up Button
Function
Select
012
34
56
789AB
C
D