![Rosito BisanI CPG Скачать руководство пользователя страница 7](http://html1.mh-extra.com/html/rosito-bisani/cpg/cpg_installation-operation-and-service-manual_1488656007.webp)
Page 7 / 18
After cooking, turn off the main burner by turning knob 1 of figure 3 onto position 1 of fig. 3a and
turn off the pilot flame by turning it onto the off position (0 of fig. 3a), wait for at least five
minutes before draining off the water by moving the lever into the open position and finally
proceed with cleaning.
CAUTION: Remember to close the gas interception cock.
5.3 Instructions to prevent accidents
The personnel assigned to using the electric cooker must keep to the instructions specified in this
manual. If the operator has not been sufficiently well trained, operation will not be optimum and
the risks concerning safety will increase.
it is compulsory to:
∗
Fill the basin with water up to a level between the two notches.
∗
Carry out all the routine maintenance and cleaning operations listed below.
∗
Keep the surfaces that can come into contact with foodstuffs clean.
∗
Make sure the gas pipes are always sound and well connected.
∗
Service the burners periodically, at least once a year.
it is forbidden to:
∗
Use the appliance dry.
∗
Keep or place inflammable objects by the appliance.
∗
Clean the machine using direct jets of water or high-pressure equipment.
∗
Put your hands or other parts of your body into the water in the basin while the machine is in
operation, or when the cooker is switched off but with the water still hot.
∗
Use objects that are not suitable for contact with foodstuffs to contain the pasta to be cooked.
CHAP 6 - TROUBLE SHOOTING
CAUTION: For all the operations described below, close the gas interception cock and
turn to specialized and authorized personnel who have an adequate knowledge of the
functions of the various parts and of the precautions to be taken.
Below are listed some possible malfunctioning and the likely cause and remedy, if the problem is
not solved or is not contemplated for in the following table, call our customer technical service :
MALFUNCTIONING LIKELY
CAUSE
REMEDY
The pilot burner will not
ignite
∗
malfunctioning of the spark plug
∗
insufficient pressure at the pilot
burner
∗
Check the spark plug fixing
∗
Check the cable and the connections
with the igniter and the spark plug
∗
Check the igniter and the spark plug
and replace them if necessary.
∗
Check the supply pressure (§ 2.4.1)
∗
Check the nozzle and clean it or replace
it if necessary.
∗
Check the valve
The pilot burner goes
out as soon as the knob
is released
∗
The pilot burner does not sufficiently
heat the thermocouple
∗
insufficient pressure at the valve
∗
Repeat the operation, pressing the
valve knob in more fully
∗
Check the relative position of the
pilot and of the thermocouple.
∗
Check the supply pressure (§ 2.4.1)
∗
Check the valve
The main burner will not
ignite even if the pilot
burner is ignited
∗
insufficient pressure at the burner
∗
burner holes clogged
∗
Check the supply pressure and the
pressure at the nozzle (§ 2.4.1)
∗
Check the valve
∗
Check the nozzle and clean or replace it
if necessary.
∗
Clean the burner.