After cooking, turn off the main burner by turning knob 1 of figure 3 onto position 1 of fig. 3a and 

turn off the pilot flame by turning it onto the off position (0 of fig. 3a), wait for at least five 
minutes before draining off the water by moving the lever into the open position and finally 
proceed with cleaning. 

CAUTION: Remember to close the gas interception cock. 

 

5.3 Instructions to prevent accidents 
 

The personnel assigned to using the electric cooker must keep to the instructions specified in this 

manual. If the operator has not been sufficiently well trained, operation will not be optimum and 
the risks concerning safety will increase. 

 

 it is compulsory to: 

∗ 

Fill the basin with water up to a level between the two notches. 

∗ 

Carry out all the routine maintenance and cleaning operations listed below. 

∗ 

Keep the surfaces that can come into contact with foodstuffs clean. 

∗ 

Make sure the gas pipes are always sound and well connected. 

∗ 

Service the burners periodically, at least once a year. 

 

 

it is forbidden to: 

∗ 

Use the appliance dry. 

∗ 

Keep or place inflammable objects by the appliance. 

∗ 

Clean the machine using direct jets of water or high-pressure equipment. 

∗ 

Put your hands or other parts of your body into the water in the basin while the machine is in 
operation, or when the cooker is switched off but with the water still hot. 

∗ 

Use objects that are not suitable for contact with foodstuffs to contain the pasta to be cooked.   

CHAP 6 - TROUBLE SHOOTING 

 CAUTION: For all the operations described below, close the gas interception cock and 

turn to specialized and authorized personnel who have an adequate knowledge of the 
functions of the various parts and of the precautions to be taken. 

Below are listed some possible malfunctioning and the likely cause and remedy, if the problem is 

not solved or is not contemplated for in the following table, call our customer technical service : 

 

MALFUNCTIONING LIKELY 

CAUSE 

REMEDY 

The pilot burner will not 
ignite 

∗ 

malfunctioning of the spark plug 

 

 

 

 

 

 

 

 

∗ 

insufficient pressure at the pilot 
burner  

∗ 

Check the spark plug fixing 

∗ 

Check the cable and the connections 
with the igniter and the spark plug 

∗ 

Check the igniter and the spark plug 
and replace them if necessary. 

∗ 

Check the supply pressure (§ 2.4.1) 

∗ 

Check the nozzle and clean it or replace 
it if necessary. 

∗ 

Check the valve

 

The pilot burner goes 
out as soon as the knob 
is released 

∗ 

The pilot burner does not sufficiently 
heat the thermocouple 

 

 

 

 

∗ 

insufficient pressure at the valve

 

∗ 

Repeat the operation, pressing the 
valve knob in more fully 

∗ 

Check the relative position of the 
pilot and of the thermocouple. 

∗ 

Check the supply pressure (§ 2.4.1) 

∗ 

Check the valve

 

The main burner will not 
ignite even if the pilot 
burner is ignited 

∗ 

insufficient pressure at the burner 

 

 

 

 

 

 

 

 

 

 

∗ 

burner holes clogged

 

∗ 

Check the supply pressure and the 
pressure at the nozzle  (§ 2.4.1) 

∗ 

Check the valve 

∗ 

Check the nozzle and clean or replace it 
if necessary. 

∗ 

Clean the burner.

 

Содержание CPG

Страница 1: ...Page 1 18 INSTALLATION OPERATION AND SERVICE MANUAL GAS COOKER MODEL CPG ...

Страница 2: ...ig 3 45 kPa Make certain that the air intake openings in the bottom of the appliance are not obstructed They are essential for proper combustion and operation of appliance Maintain adequate clearance in front of unit for servicing and proper operation NOTE All servicing can be done through front door This equipment is to be installed to comply with the appliance Federal State or local plumbing cod...

Страница 3: ...315 CPG7 2 62000 18kW 630 Table 1 1 Minimum change of air in relation to the thermal power installed Clearances Combustible construction Noncombustible construction Side 6 0 0 Rear 6 0 0 Floor 6 0 0 Ceiling 48 0 Table 1 2 Clearances from combustible and noncombustible construction 2 2 Handling and Unpacking To move the machine to the place of installation use a fork lift truck Do not drag the appl...

Страница 4: ...hown in table 2 2 it is not possible to go ahead with installation and it is necessary to inform the gas board of the anomaly with the mains 6 Close the gas interception cock disconnect the pressure gauge screw the closing screw back on and close the front door Type of gas Supply pressure Inches Water Column kPa minimum maximum rated natural gas methane G20 3 5 0 87 10 5 2 61 7 0 1 74 Tab 2 2 Perm...

Страница 5: ... not previously been authorized by the manufacturer frees the manufacturer from damage deriving from or referable to the above mentioned acts CHAP 4 SPECIFICATION MODELS CPG 1 Gas unit with a single tank of 10 56 gallons CPG 2 Gas unit with two tanks of 10 56 gallons each CPG 3 Gas unit with three tanks of 10 56 gallons each CPG 7 1 Gas unit with a single tanks of 7 4 gallons CPG 7 2 Gas unit with...

Страница 6: ...e gas the gas control knob If it will not push in or turn by hand don t try to repair it call a qualified service technician Force or attemped repair may result in a fire or explosion 3 Don t use this appliance if any part has been under water call a qualified service technician to inspect the appliance and to replace any part which has been under water 5 2 Lighting and shutdown instructions 1 Car...

Страница 7: ...e not suitable for contact with foodstuffs to contain the pasta to be cooked CHAP 6 TROUBLE SHOOTING CAUTION For all the operations described below close the gas interception cock and turn to specialized and authorized personnel who have an adequate knowledge of the functions of the various parts and of the precautions to be taken Below are listed some possible malfunctioning and the likely cause ...

Страница 8: ...ooms periodically The periodical annual maintenance of the burners must be done by specialized and authorized personnel and it consists of keeping the holes clean for the fuel comburent mixture to flow in and out Access to the burners and nozzles is explained in the following paragraphs 7 1 Special maintenance The special maintenance procedures should be carried out by qualified and authorized per...

Страница 9: ...u have cut off the gas supply remove the door by unscrewing the screw fixing it to the support 2 Remove the water inlet knob 1 of fig 3 and unscrew the two screws fixing the instrument panel to the under panel Remove the instrument panel 3 Disconnect from the valve the supply pipe the pipe that goes to the burner and the one that goes to the pilot burner and the thermocouple pos 1 4 6 and 5 of fig...

Страница 10: ...Page 10 18 A water supply connection φ 1 2 B water outlet connection φ 1 G gas supply connection φ 1 2 Figure 1 Overall dimensions and position of the piping CPG 1 CPG 2 CPG 1 CPG 2 ...

Страница 11: ...11 18 A water supply connection φ 1 2 B water outlet connection φ 1 G gas supply connection φ 1 2 Figure 1 Overall dimensions and position of the piping CPG 3 Figure 1b Removable top flue grid assembly CPG 3 ...

Страница 12: ...Page 12 18 A water supply connection φ 1 2 B water outlet connection φ 1 G gas supply connection φ 1 2 Figure 1 Overall dimensions and position of the piping CPG 7 1 CPG 7 2 CPG 7 1 CPG 7 2 ...

Страница 13: ...l 4 Left panel 5 Rear panel 6 Top 7 Flue gas outlet grille 8 Foam collection grille 9 Outlet grille 10 Under panel 11 Front panel 12 Water inlet knob 14 Door 15 Magnet 16 Door support plate 18 Door pivot Figure 2 Gas cooker CPG 1 2 3 7 1 7 2 components ...

Страница 14: ...ter inlet knob 6 Water knob disk 7 Copper pipe from supply to cock Figure 2a Water supply 1 Rubber overflow pipe 3 Outlet cock pipe fitting 4 Outlet cock 5 Outlet rubber pipe fitting 6 Outlet cock lever 7 Copper pipe from cock lever 8 Lever extension Figure 2b Water outlet ...

Страница 15: ... 6 Outlet cock lever 7 Copper pipe from cock to jet 8 Lever extension 9 Rubber overflow pipe Figure 2b CPG 2 CPG 7 2 water outlet 1 Water inlet knob 2 Safety valve 3 Valve reference Figure 3 Instrument control panel 0 Closed valve 1 Open pilot burner 2 Minimum 3 Maximum Figure 3a Valve knob positions ...

Страница 16: ...age 16 18 1 Main burner 2 Union 3 Nozzle fixing nut 4 Main nozzle Figure 4 Main burner 1 Pilot burner 3 Gas pipe 4 Thermocouple 5 Spacer 6 Pilot nozzle 7 Fixing nuts 8 Fixing plate Figure 5 Pilot burner ...

Страница 17: ...e from valve to burner 5 Thermocouple 6 Pilot gas pipe 7 Pilot pipe valve union 8 Valvle 9 Pressure tube screw 10 Pressure tube washer 11 Fixing washer 12 Fixing nut Figure 6 Gas supply unit Figure 5a Manual ignition A Minimum adjustment screw Figure 7 Safety valve ...

Отзывы: