If you cannot reach your gas supplier call the fire department.
CHAP 2 - INSTALLATION
2.1 Preliminary instructions
Installation must be carried out by following the instructions contained in this handbook and only by
a licensed tradesman in accordance with local codes, or in absence of it, with the National Fuel
Gas Code, ANSI Z 223.1 or with the Natural Gas Installation Code CAN/CGA-B149.1. The
manufacturer cannot be held liable for any damage caused by faulty installation.
The place where the machine is to be installed must have aeration equal to at least that
given in table 1.1
, this is in order to supply the necessary air for combustion, to prevent
reaching too high percentages of gas and to aid evacuation of the products of combustion.
The installation room must be in conformity with the current fire regulations.
The unit must operate in a level position. Slight floor irregularities can be conpensated by turning
the adjustable feet of the cooker either clockwise or counterclockwise.
Clearances from combustible and noncombustible construction are given in table 1.2
model
Power (BTU/hr)
Air flow (m
3
/h)
CPG1
60000 (13.2 kW)
490
CPG2
120000 (26.4 kW)
980
CPG3
180000 (39.6kW)
1470
CPG7/1
31000 (9kW)
315
CPG7/2
62000 (18kW)
630
Table 1.1 Minimum change of air in relation to the thermal power installed
Clearances
Combustible construction
Noncombustible construction
Side
6.0 ”
0 “
Rear
6.0 ”
0 “
Floor
6.0 ”
0 “
Ceiling
48.0 ”
Table 1.2 Clearances from combustible and noncombustible construction
2.2 Handling and Unpacking
To move the machine to the place of installation, use a fork-lift truck. Do not drag the appliance on
the floor.Take the adhesive protection off the steel surfaces, taking care not to leave any
remains of glue, in which case use appropriate thinners to remove them.
2.3 Connecting to the water-main
The unit should be connected to your water supply by way of a water faucet. The water pressure
should fall between 14.5 and 72.5 PSI. If the water pressure is excessive, a pressure regulator
must be installed.
The pipe used to discharge the water must be heat resistant and allow for the free flow of the
discharge water. A funnel may be used between the unit discharge pipe and the floor drain but
tou should never restrict or reduce the diameter of the discharge pipe.
The following operations are to be carried out only by specialized technical personnel.
Having verified that available water system is adequate you can go ahead and make connection:
1. Clear the pipe of any ferrous waste by letting a certain amount of water flow through.
2. Place the cooker in the desired position and close to the water-main.