9
IV. Bulb Replacement
1.Switch the unit off and unplug the appliance.
2.Remove the lamp cover by unscrewing the 2 screws.
3.Unscrew the incandescent bulb
4.Replace with the same type and rated lamp
LED lamp (max,1.5W).
Replace bulb
Remove the screws on the glass, and remove it. Find the bulb that needs
to be replaced, you will find it located inside the base of the hood.
TROUBLESHOOTING
Fault
Cause
Solution
Light on, but fan
does not work
The fan blade is jammed.
Switch off the unit and repair by
qualified service personnel only.
The motor is damaged.
Both light and
fan do not work
light bulb burn.
Replace the bulb with correct rating.
Power cord looses.
Plug into the power supply again.
Serious
Vibration of the
unit
The fan blade is
damaged.
Switch off the unit and repair by
qualified service personnel only.
The fan motor is not fixed
tightly.
Switch off the unit and repair by
qualified service personnel only.
The unit is not hung
properly on the bracket.
Take down the unit and check
whether the bracket is in proper
location.
Suction
performance
not good
Too long distance
between the unit and the
cooking plane
Readjust the distance to 65-75cm
ENVIRONMENTAL PROTECTION
Waste electrical products should not be disposed of with
household waste. Please recycle where facilities exist. Check
with your Local Authority or retailer for recycling advice.
Содержание RVSD9800PN
Страница 1: ...INSTALLATION AND USER S MANUAL ...