- 30
If the gas type has been altered, the stability of the flame in the minimum
flow must be checked and set by adjusting the bypass screw.
To access the top burner bypass screw, remove the control panel knobs.
a) natural gas
. unscrew the bypass screw one turn
. replace the knob, light the burner and set to low.
. remove the knob, screw the bypass screw until a reduced flame is
obtained, staying stable when going from high to low position. Replace the knob.
b) butane-propane:
the setting is done by screwing right in (without
forcing) the bypass screw whose calibrated hole provides the minimum flow.
To access the hob burner’s bypass screw, remove its knob.
a) natural gas:
screw the bypass screw right in then unscrew it by two
turns, replace the knob and light the burner, set it to low (to the stop), remove
the knob, and screw the bypass screw to obtain a low flame that stays
stable when going from high to low position. Replace the knob.
b) butane-propane:
the setting is done by screwing to the stop the bypass
screw whose calibrated hole provides the minimum flow.
burner
bypass screw
MINIMUM FLOW ADJUSTMENT
Содержание Bocuse
Страница 1: ...1 44000571 The Rosières Bocuse cooker Operating instructions B O C U S E RBC 127 AUS ...
Страница 34: ... 34 ...
Страница 35: ...35 ...