1.4 Kit Documentation 

 

USB-Stick

  

Standard Definitions as data files for Vector Network Anaylzer Families PNA 
(Keysight/Agilent) and ZVA (Rohde&Schwarz). Calibration Certificate as PDF-file. 

 

Standard Definitions Cards

 

Printed Standard Definitions that can be used on nearly all Vector Network Analyzers. 

 

Kit Info Card

 

Handling precautions and information for installing Standard Definitions on a Vector Network 
Analyzer. 

 

Calibration Certificate

 

See chapter Calibration Certificate.  

 

User Manual

 

(This document) 

 

 

1.5 Calibration Certificate 

 

Each calibration kit comes with a calibration certificate. Measurement results and uncertainties for 
all calibration standards, the Gauges and the Torque Wrench are included.  
 
Standard scope of delivery is the Factory Calibration.  
 
Optional  scope  of  delivery  is  the  Accredited  Calibration.  In  this  case  the  electrical  calibration 
standards  of  this  calibration  kit  are  calibrated  instead  in  the  Rosenberger  calibration  laboratory, 
which  is  accredited  by  the  German  accreditation  body  DAkkS  (Deutsche  Akkreditierungsstelle) 
according  to  DIN  EN  ISO  17025.  Calibration  Certificates  issued  by  an  accredited  calibration 
laboratory  are  accepted  worldwide  to  demonstrate  that  measurement  results  are  traceable  to 
national / international standards. 
 

 

 

Содержание 60CK001-150

Страница 1: ...nztechnik GmbH Co KG P O Box 1260 D 84526 Tittmoning Germany www rosenberger com Tel 49 8684 18 0 Email info rosenberger com Page 1 17 Dieses Dokument ist urheberrechtlich gesch tzt This document is p...

Страница 2: ...it Documentation 1 4 Calibration Certificate 1 5 2 Specifications Environmental Requirements 2 1 Electrical and mechanical Specifications 2 2 3 Standard Definitions Standard Definitions 3 1 Installati...

Страница 3: ...t used Contributing factors are noise linearity and temperature stability of the VNA transmission and reflection stability of a test port cable as well as operator experience and care VNAs usually off...

Страница 4: ...n adaptor plug plug 60S121 S20S3 1 Calibration adaptor jack jack 60K121 K20S3 1 Calibration adaptor RPC N plug to 7 16 plug 05S160 S20S3 1 Calibration adaptor RPC N jack to 7 16 jack 05K160 K20S3 1 Co...

Страница 5: ...for installing Standard Definitions on a Vector Network Analyzer Calibration Certificate See chapter Calibration Certificate User Manual This document 1 5 Calibration Certificate Each calibration kit...

Страница 6: ...are defined for all calibration standards gauges and the torque wrench in the specific data sheets 3 Standard Definitions 3 1 Standard Definitions Standard definitions provide the data needed to math...

Страница 7: ...more complex process Please consult the VNA operating manual Some network analyzers allow a step by step input of the model based standard definitions during the VNA calibration without previously lo...

Страница 8: ...etting parameters Sweep type linear logarithmic Sweep range start frequency stop frequency Number of points frequency step size Source power IF bandwidth small IF bandwidth basically increases the dyn...

Страница 9: ...rts and is most effective when data based standards are available In cases when the two VNA test ports have different connector systems installed e g 7 16 and RPC N 50 UOSM can handle this situation A...

Страница 10: ...s office Please use the Service Form at the end of this manual if there are any known problems with your calibration kit 5 4 Extent of Rosenberger Re Calibration Services Every calibration kit sent fo...

Страница 11: ...d connector repeatability and its effect on the overall uncertainty of a measurement procedure should encourage careful inspection interface gauging and handling of coaxial connectors Prior to use a v...

Страница 12: ...ear at least a grounded wrist strap and observe correct procedures 6 2 Interface Dimensions and Gauging It is of the utmost importance that connectors do not damage the test equipment interfaces to wh...

Страница 13: ...a gauge jack female all gender are vice versa Checking devices for protrusion or excessive recession only a single measurement is sufficient More precise measurements or checking devices very close t...

Страница 14: ...17 Dieses Dokument ist urheberrechtlich gesch tzt This document is protected by copyright Rosenberger Hochfrequenztechnik GmbH Co KG 6 2 4 Gauge blocks Every connector gauge requires a gauge block tha...

Страница 15: ...r extends beyond the reference length This means a pin depth 1 77 mm on the male connector and a pin depth of 1 77 mm on the female connector Protrusion may result in buckling of the socket contacts o...

Страница 16: ...ectors Refer to 6 1 Connector Care 4 Use a connector gauge to verify that all centre conductors do not protrude the pin depth values in Figure 6 2 5 Carefully align the connectors The male connector c...

Страница 17: ...disconnecting a sliding load leave the centre conductor pullback handle in the locked position Use the combi wrench to prevent the device body from turning Use torque wrench to loosen the connecting...

Отзывы: