1.  General Information 

 

This User Manual is valid for the Calibration Kits  

 

06CK001-150 (Full Version) 

 

 

06CK010-150 (Industrial Version)

 

 

Customer specific RPC-TNC Calibration Kits, excluding Air Line Kits

 

 

The Industrial Version does not contain gauges. So all gauge related chapters are only applicable if 
additional gauges are available, e.g. Rosenberger 06GK0KS-010 or comparable ones. 
For customer specific Calibration Kits all VNA calibration methods may not be available. 

 

1.1 Calibration Kit Normal Use 

 

Calibration Kits are used as an accessory for Vector Network Analyzers (VNA) to perform vector-
error  correction.  Vector-error  correction  is  the  process  of  characterizing  systematic  errors  of  the 
measurement  system  by  measuring  known  calibration  standards,  and  then  mathematically 
removing the effects of these errors from subsequent measurements. The measurement accuracy 
of the calibrated VNA depends mainly on the quality of the calibration kit used. Contributing factors 
are noise, linearity and temperature stability of the VNA, transmission  and reflection stability of a 
test port cable as well as operator experience and care. 

 

VNAs  usually  offer  several  techniques  for  correcting  systematic  measurement  errors.  The 
standards  in  this  calibration  kit  allow  you  to  perform  one-port  OSL  (OSM)  or  two-port  OSLT 
(TOSM) and TRM (TMR) calibrations from DC up to 18 GHz for measurements of components with 
RPC-TNC connectors. 

 

Components with other TNC connectors are mechanically compatible and can also be measured.  

 

1.2 Warnings 

 

The calibration standards and the gauges of this calibration kit are mechanically sensitive devices. 
High accelerations e.g. when falling down will damage them.  

 

Connect the calibration standards only to test ports and other devices that have been cleaned and 
checked  for  gauge,  concentricity  and  integrity  of  the  contact  fingers.  Detailed  procedures  are 
described in Chapter 6 and 7. 

 

Tighten  the  connector  coupling  nuts  to the recommended  torque  with the  torque  wrench. Do  not 
over torque! 

 

Consider the power applied to the Load calibration standards. Maximum power limits for the sum of 
RF and DC power are defined in the specific data sheets. 

 

It is  good  lab practice  to use  at  least  an  ESD  wrist  strap  when  handling calibration  standards  or 
DUTs  on  a  VNA  although  the  calibration  standards  themselves  are  not  ESD  sensitive.  Please 
consult your VNA manual. 

 

Follow further limitations given in the specific data sheets.

 

 

Содержание 06CK001-150

Страница 1: ...enztechnik GmbH Co KG P O Box 1260 D 84526 Tittmoning Germany www rosenberger com Tel 49 8684 18 0 Email info rosenberger com Page 1 18 Dieses Dokument ist urheberrechtlich gesch tzt This document is...

Страница 2: ...Kit Documentation 1 4 Calibration Certificate 1 5 2 Specifications Environmental Requirements 2 1 Electrical and mechanical Specifications 2 2 3 Standard Definitions Standard Definitions 3 1 Installa...

Страница 3: ...ibration kit used Contributing factors are noise linearity and temperature stability of the VNA transmission and reflection stability of a test port cable as well as operator experience and care VNAs...

Страница 4: ...it Device Part number Remarks Quantity Open circuit plug 06S12L 000S3 1 Open circuit jack 06K12L 000S3 1 Short circuit plug 06S12S 000S3 1 Short circuit jack 06K12S 000S3 1 Calibration load plug 06S15...

Страница 5: ...alibration load jack 06K150 C10S3 1 Calibration adaptor plug plug 06S121 S20S3 1 Calibration adaptor jack jack 06K121 K20S3 1 Calibration adaptor plug plug 05S106 S20S3 1 Calibration adaptor jack jack...

Страница 6: ...t results and uncertainties for all calibration standards the Gauges and the Torque Wrench are included Standard scope of delivery is the Factory Calibration Optional scope of delivery is the Accredit...

Страница 7: ...s are defined for all calibration standards gauges and the torque wrench in the specific data sheets 3 Standard Definitions 3 1 Standard Definitions Standard definitions provide the data needed to mat...

Страница 8: ...a more complex process Please consult the VNA operating manual Some network analyzers allow a step by step input of the model based standard definitions during the VNA calibration without previously l...

Страница 9: ...setting parameters Sweep type linear logarithmic Sweep range start frequency stop frequency Number of points frequency step size Source power IF bandwidth small IF bandwidth basically increases the dy...

Страница 10: ...available In cases when the two VNA test ports have different connector systems installed e g RPC TNC and RPC 3 50 UOSM can handle this situation A second calibration kit is needed Calibration Procedu...

Страница 11: ...calibration or repair contact your local Rosenberger sales office 5 4 Extent of Rosenberger Re Calibration Services Every calibration kit sent for re calibration or repair the following services are...

Страница 12: ...od connector repeatability and its effect on the overall uncertainty of a measurement procedure should encourage careful inspection interface gauging and handling of coaxial connectors Prior to use a...

Страница 13: ...the utmost importance that connectors do not damage the test equipment interfaces to which they are connected Poor performance of many coaxial devices and cable assemblies can often be traced to poor...

Страница 14: ...ical limits should be done in different orientations averaging up to 4 single measurements When a gauge block is used to initially adjust the gauge a torque spanner should be used to tighten up the co...

Страница 15: ...rger com Tel 49 8684 18 0 Email info rosenberger com Page 15 18 Dieses Dokument ist urheberrechtlich gesch tzt This document is protected by copyright Rosenberger Hochfrequenztechnik GmbH Co KG Figure...

Страница 16: ...in which the centre conductor extends beyond the outer conductor mating plane This may result in buckling of the socket contacts or damage to the internal structure of a device due to the axial force...

Страница 17: ...centre conductors are within the observed pin depth values in Table 2 2 Refer to 4 2 Interface Dimensions and Gaging 5 Carefully align the connectors The male connector centre pin must slip concentri...

Страница 18: ...n disconnecting a sliding load leave the centre conductor pullback handle in the locked position Use the combi wrench to prevent the device body from turning Use torque wrench to loosen the connecting...