Quick Installation Guide
00825-0100-4750, Rev BA
June 2009
Rosemount 8750WA
9
S
TEP
4: I
NSTALLATION
Flanged Sensors
Gaskets
The sensor requires a gasket at each of its connections to adjacent devices or piping. The gasket
material selected must be compatible with the process fluid and operating conditions. Metallic or
spiral-wound gaskets can damage the liner. Gaskets are required on each side of a
grounding ring. All other applications (including sensors with lining protectors or a grounding
electrode) require only one gasket on each end connection.
Flange Bolts
Suggested torque values by sensor line size and liner type are listed in Table 1. Consult the
factory if the flange rating of the sensor is not listed. Tighten flange bolts on the upstream
side of the sensor in the incremental sequence shown in Figure 6 to 20% of the suggested
torque values. Repeat the process on the downstream side of the sensor. For sensors with
more or less flange bolts, tighten the bolts in a similar crosswise sequence. Repeat this
entire tightening sequence at 40%, 60%, 80%, and 100% of the suggested torque values or
until the leak between the process and sensor flanges stop.
If leakage has not stopped at the suggested torque values, the bolts can be tightened in
additional 10% increments until the joint stops leaking, or until the measured torque value
reaches the maximum torque value of the bolts. Practical consideration for the integrity of
the liner often leads the user to distinct torque values to stop leakage due to the unique
combinations of flanges, bolts, gaskets, and sensor liner material.
Check for leaks at the flanges after tightening the bolts. Failure to use the correct tightening
methods can result in severe damage. Sensors require a second tightening 24 hours after
the initial installation. Over time, sensor liner materials may deform under pressure.
Figure 6. Flange Bolt Torquing Sequence
1
5
3
7
8
4
6
2
8-bolt
4750RevBAQIG.fm Page 9 Thursday, July 16, 2009 3:52 PM
Содержание 8750WA
Страница 37: ...Quick Installation Guide 00825 0100 4750 Rev BA June 2009 Rosemount 8750WA 37 ...
Страница 38: ...Quick Installation Guide 00825 0100 4750 Rev BA June 2009 Rosemount 8750WA 38 ...
Страница 39: ...Quick Installation Guide 00825 0100 4750 Rev BA June 2009 Rosemount 8750WA 39 ...
Страница 40: ...Quick Installation Guide 00825 0100 4750 Rev BA June 2009 Rosemount 8750WA 40 ...