Reference Manual
00809-0100-4026, Rev FA
July 2009
Rosemount 5400 Series
7-6
Figure 7-3. Example 2: surface
threshold is too low.
By adjusting the surface threshold, the product surface is properly detected,
Figure 7-4. Echo Curve after
surface threshold was adjusted
To adjust the amplitude thresholds, see “Using the Echo Curve Analyzer” on
page 7-9.
In the
Echo Curve Analyzer
in RRM, the amplitude threshold points can easily
be dragged to the desired values.
Amp
litu
d
e, m
V
Actual surface
Surface Threshold=
Amplitude Threshold
Curve (ATC)
Distance, m
P1 - Disturbing echo
misinterpreted as
product surface
Reference
Amp
litu
d
e, m
V
Distance, m
After Surface Threshold is
adjusted, the product surface is
correctly detected
Surface Threshold=
Amplitude Threshold
Curve (ATC)
Reference
Содержание 5401
Страница 2: ......
Страница 4: ......
Страница 10: ...Reference Manual 00809 0100 4026 Rev FA July 2009 Rosemount 5400 Series TOC 6 ...
Страница 24: ...Reference Manual 00809 0100 4026 Rev FA July 2009 Rosemount 5400 Series 2 10 ...
Страница 80: ...Reference Manual 00809 0100 4026 Rev FA July 2009 Rosemount 5400 Series 5 26 ...
Страница 90: ...Reference Manual 00809 0100 4026 Rev FA July 2009 Rosemount 5400 Series 6 10 ...
Страница 160: ...Reference Manual 00809 0100 4026 Rev FA July 2009 Rosemount 5400 Series B 16 ...
Страница 174: ...Reference Manual 00809 0100 4026 Rev FA July 2009 Rosemount 5400 Series C 14 ...
Страница 177: ...Reference Manual 00809 0100 4026 Rev FA July 2009 Index 3 Rosemount 5400 Series ...
Страница 178: ...Reference Manual 00809 0100 4026 Rev FA July 2009 Rosemount 5400 Series Index 4 ...
Страница 179: ......