4.0 Troubleshooting and remedy
Fault
Cause
Remedy
Machine can not be started
Lifting spindles (18) are not in
with AUTOSTART end position
Press LOWER key (6) once
again
Machine cleans poorly
Spray nozzle (37) is blocked
Clean spray nozzle (37)
Brushes (24) are soiled
Clean brushes (24)
Brushes (24) are worn
Replace brushes (24)
Detergent return to the
machine is too low
Seal strip (22) is defect
Replace seal strip (22)
Suction basin (21) is set
incorrectly
Adjust suction basin (21)
Stripping Brush (23) is dirty
Remove suction basin (21)
and clean striping brush (23)
Dirt streaks are visible on front
travelator face
Stripping Brush (23) is dirty
Remove suction basin (21)
and clean stripping brush (23)
Stripping Brush (23) is worn
Remove suction basin (21)
and replace stripping brush
(23)
Water residues on travelator
Cover (1) of dirty-water tank
(2) does not close tight
Attach cover (1)
Replace tank cover (1)
If the fault in the machine can not be
remedied according to the procedures
described in the table above, the customer
service of Rosemor International Ltd should
be notified and the necessary repair work
carried out by its staff.