background image

ENGINEERING STANDARDS

Rosedale Products, Inc.

IOM

Issue Date: 29MAY96

3730 West Liberty Road

D6150STD.WP6

Revision:  

Ann Arbor, MI 48103

n:\iom\

Revision Date:  

Specification No.

7.3.4

PAGE:  2 of 6 

INSTALLATION, OPERATION, & MAINTENANCE MANUAL

Rosedale Engineering Standards are the property of Rosedale Products, Inc.  A Rosedale standard or copy thereof shall not be distributed (except with express approval of Rosedale
Products, Inc.) to any individual or firm beyond the intended recipient firm or individual.  Firms of individuals acting contrary to the above may be subject to suit, ineligibility for continued or
future employment, or removal from Rosedale's "Approved Manufacturers and Specialty Contractors List".

I.

Installation

P lease remove all shipping and crating materials carefully.  Be sure to remove the plugs from the inlet and outlet
openings.  Dispose of all crating materials safely.

After positioning the Model 6 Duplex Filter unit in its proper location, secure the adjustable tripod leg assemblies to
the floor or platform.  (Some installations may not require the adjustable tripod leg assemblies.)

The duplex system is normally supplied with the inlet-outlet connections in a horizontal orientation (facing in
opposite directions) as shown on the last page of this manual.  However, the inlet-outlet orientations can be varied
depending on your application.

The inlet service line should be connected to the inlet flange or NP T coupling located near the top of the units (above
basket level).

The outlet service line should be connected to the outlet flange or NP T coupling, located near the middle or bottom
of the units (below basket level).

There are two 1/4" NP T ports, one on the inlet tee and one on the outlet tee, of the Model 6 Duplex Filter unit. 
Additionally, there is one 1/4" NP T port in each cover of the Model 6 Duplex Filter unit.  These ports can remain
plugged or used for pressure gauges, or special fittings as your application requires.

Some installations require electrical grounding of all equipment, be sure to provide adequate grounding where
necessary.

After completing installation be sure to double check connections for integrity.  Your Model 6 Duplex Filter unit has
been factory pressure tested leak free, therefore, any seepage problems usually occur from improper installation
connections.

You are now ready to install the filter baskets and bags. (Your Rosedale Model 6 Duplex Filter unit consists of two
Rosedale Model 6 Filter units.  They are designed for continual flow through one unit while servicing the other). 
Remove cover by loosening the cover eyenuts on one of the filters.  The eyenuts in the slotted corners should be
loosened sufficiently to swing free.  Loosen the third eyenut sufficiently to allow the top cover and closure assembly
to swing away from the top of the unit.

P lace the basket into the filter housing, make sure the basket flange is firmly seated on top of the basket collar.

Insert bag into the bag basket making sure filter bag ring is firmly seated on top of the basket flange.  For best
results, be sure filter bag is installed fully extended to the bottom of the basket.

Before replacing cover assembly, inspect cover seal gasket (replacing as necessary).  Close cover and alternately
tighten the three clamp assemblies evenly to ensure a leak proof seal between the cover and housing body.  The
recommended torque value for 5/8"-11 closure assemblies is 150

.  Repeat the above steps for installing the filter

ft-lb s

basket and bag for the other unit.

Your Rosedale Model 6 Duplex Filter unit is now ready for operation!

Содержание DUPLEX 6

Страница 1: ...distributed except with express approval of Rosedale Products Inc to any individual or firm beyond the intended recipient firm or individual Firms of individuals acting contrary to the above may be subject to suit ineligibility for continued or future employment or removal from Rosedale s Approved Manufacturers and Specialty Contractors List INSTALLATION OPERATION AND MAINTENANCE MANUAL ROSEDALE P...

Страница 2: ...e inlet tee and one on the outlet tee ofthe Model 6 Duplex Filter unit Additionally there is one 1 4 NPT port in each cover ofthe Model 6 Duplex Filter unit These ports can remain plugged or used for pressure gauges or special fittings as your application requires Some installations require electrical grounding ofall equipment be sure to provide adequate grounding where necessary After completing ...

Страница 3: ...d more than 15 PSI Differential Pressure through the filter be obtained Operating the filter unit with a high differential may cause filter bags to rupture and or cause damage to filter systemand downstream equipment To prevent excessive drop through the filter unit regular inspection ofthe filter media is required Monitoring of differential pressure through the housing can be utilized as a means ...

Страница 4: ...bag is installed fully extended to the bottomofthe basket 13 Inspect cover gasket for cuts or other signs offailure and make sure it is properly seated 14 Move cover back into position and alternately tighten the three clamp assemblies evenly to ensure a leak proofseal between cover and housing body The recommended torque value for 5 8 11 closure assemblies is 150ft lbs Your Rosedale Model 6 Duple...

Страница 5: ...s are the property of Rosedale Products Inc A Rosedale standard or copy thereof shall not be distributed except with express approval of Rosedale Products Inc to any individual or firm beyond the intended recipient firm or individual Firms of individuals acting contrary to the above may be subject to suit ineligibility for continued or future employment or removal from Rosedale s Approved Manufact...

Страница 6: ...aleproducts com Important Notice Warranty In the event any Rosedale Products Inc filtration product is found to be defective in material workmanship or not in conformance with any express warranty for a specific purpose Rosedale s only obligation and your exclusive remedy shall be to repair replace or refund the purchase price of such parts or products upon timely notification thereof and substant...