Appendix C. Rack mount instructions
The optional rack mount kit includes the following items:
Two black anodized mounting brackets or
3 unit mounting shelf.
6 - 32 x 3/8” flat head mounting screws.
To rack mount a single unit, attach the two rack mounting brackets to your
Unit with the short flange against the Unit or mount up to three units on the
Rackmount shelf. Do not over tighten the screws used to mount the Unit to
the mounting brackets or shelf. Use only the hardware provided, using
hardware other than that provided could cause damage to the electronics
and/or result in loss of mounting integrity. Secure the mounting brackets or
the shelf to the rack using the appropriate size bolts, nuts and lock washers.
The following guidelines should be observed when installing.
a).
Do not exceed the operating temperature of 0
ο
C to 40
ο
C.
b).
Do not block power supply vents or restrict airflow.
c).
Mechanical loading of the rack should be considered to prevent
instability and possible tipping over.
d).
Tighten all connectors securely and provide adequate strain relief for
all cables.
Provide a grounded power source to all Units. Pay special attention to
overall branch circuit load ratings before connecting equipment to this
source. Overloaded circuits are potential fire hazards and can cause
equipment failures or poor performance.