ORION LC Installation and Operations Manual
17
NOTE:
After the reset command “0x02, 0x54, 0X03” is issued, the Orion LC switch will reset
to the DEFAULT conditions or the previous mode settings before the reset command
or power cycle was issued based on the setting of SW7 as shown.
SW7 = OFF
After a reset the following DEFAULT- Mode is selected:
1x7: I1 to O1
2x6: I1 to O1 and I2 to O2
3x5: I1 to O1, I2 to O2 and I3 to O3
4x4: I1 to O1, I2 to O2, I3 to O3 and I4 to O4
5x3: I1 to O1, I2 to O2 and I3 to O3
6x2: I1 to O1 and I2 to O2
7x1: I1 to O1
SW7 = ON
After a reset the previous mode before a reset or power
OFF is selected.
The structure of the serial command is:
0x02, 0xCC, [0xAA……], 0x03 where:
0x02 = Send text command
0xCC = Instruction command
0xAA = Command attributes (data)
0x03 = End text command
Serial Command Examples: (Crosspoint Switch mode)
Serial Command
Description
0X02, 0x54, 0X03
Reset the switch and set the connections as a
function of SW7 (See previous SW7 NOTE)
0X02, 0x40, 0x80, 0X03
Read the version number from the switch
0X02, 0x52, 0X03
S
witch off all local / remote connections
0X02, 0x47, 0x84, 0x81, 0X03
Switch (remote) output 04 to (local) input 01
0X02, 0x47, 0x85, 0x81, 0X03
Switch (remote) output 05 to (local) input 01
(remote output 04 and 05 show the same video)
0X02, 0x47, 0x86, 0x81, 0X03
Switch (remote) output 06 to (local) input 01
(remote output 04 - 06 show the same video)
0X02, 0x47, 0x87, 0x81, 0X03
Switch (remote) output 07 to (local) input 01
(remote output 04 - 07 show the same video)
0X02, 0x66, 0x80, 0x81, 0X03
Saves active switching status as macro 1
0X02, 0x52, 0X03
Disconnect all connections (monitors are blank)
0X02, 0x67, 0x80, 0x81, 0X03
Call macro 1: (remote) output 04 - 07 show the
same video as input 01
0X02, 0x48, 0x84, 0X03
Open the connection between (remote) output 04
and the equivalent (local) input (only monitor
05 – 07 show video)
See Appendix D for a complete list of all serial switching commands