background image

10-00328 REV C 

3  LAMP OPERATION 

3.1  POWER 

AC 

Operation of the Q-LED II requires an input voltage between 0 

– 120VAC 50/60Hz. The 

lamp  draws  150  VA  of  power  at  maximum  light  intensity.    Maximum  light  intensity  is 
measured at 120 VAC.  They begin to output light at 70 VAC (typical). 
 

DC 

Although the Q-LED is intended to be an AC powered light, it can also be powered by 
DC power. The 120 VAC version can run off of DC power from 0-160 VDC. Maximum 
light intensity is measured at 160 VDC.  They begin to output light at 95 VDC (typical). 
 

3.2  TEMPERATURE PROTECTION  

The  Q-LED  II  is  electronically  protected  from  overheating  via  a  thermal  cut-off  switch. 
The light will run for approximately 4 minutes in air (at an ambient temperature of 20°C 
(68°F))  before  automatically  powering  down.  There  is  no  reset;  the  light  will 
automatically re-illuminate once it has cooled to a safe operating temperature. 

3.3  RECOMMENDED OPERATION 

The  thermal  protection  is  intended  as  a  failsafe  feature  to  protect  the  light  from 
unintentional damage from extended use in air.  It is not recommended to  intentionally 
run the light out of water for any extended period as it will reduce the product lifespan. 

4  SPECIFICATIONS 

4.1 

ELECTRICAL 

Light Model   

 

 

Operating voltage 

 

 

Turn on voltage 

120 VAC 

  

 

 

0 - 120VAC 50/60Hz 

 

70VAC 

 

 

 

 

 

– 160VDC   

 

 

95VDC 

Operating Current:   

 

1.2 A typical @ 120VAC 

 

 

 

 

 

0.5 A typical @ 160VDC 

 

 

 

 

 

 

Power Consumption: 

AC powered 

– 150 VA max at full intensity 

 

DC powered 

– 80 W typical at full intensity 

 

 

Содержание Q-LED II

Страница 1: ...OLID STATE UNDERWATER LED LAMP Q LED II 120VAC 160VDC OPERATING AND MAINTENANCE MANUAL SERIAL NUMBER __________ SALES ORDER __________ 5618 Copley Drive San Diego CA 92111 7902 TEL 858 565 8500 FAX 85...

Страница 2: ...is warranty shall be governed by the laws of the State of California In the event the defect is determined to be within the terms of this warranty then ROS agrees to repair and or replace at ROS s dis...

Страница 3: ...and are able to provide assistance during installation and or operation of these products If you have any questions or problems with this product that are not covered by this manual or instruction pl...

Страница 4: ...ATION 3 3 1 POWER 3 3 2 TEMPERATURE PROTECTION 3 3 3 RECOMMENDED OPERATION 3 4 SPECIFICATIONS 3 4 1 ELECTRICAL 3 4 2 PERFORMANCE 4 4 3 MECHANICAL 6 4 4 ENVIRONMENTAL 6 5 VIDEO COMPATIBILITY 6 6 CONNEC...

Страница 5: ...e Q LED II Like a conventional lamp light dimming is achieved by decreasing or increasing the input source voltage Lights powered by AC voltage can be dimmed using an AC phase control dimmer If powere...

Страница 6: ...a solid state LED light array The LED light engine is secured in the housing via a special assembly The forward end of the Q LED II is sealed with an o ring between the housing and a deepwater rated w...

Страница 7: ...t off switch The light will run for approximately 4 minutes in air at an ambient temperature of 20 C 68 F before automatically powering down There is no reset the light will automatically re illuminat...

Страница 8: ...original maximum output Dimming AC Powered Light is dimmed via input voltage or AC phase control DC Powered Light is dimmed via input voltage or PWM A modulation frequency of 1 kHz or higher is recom...

Страница 9: ...10 00328 REV C 5 Figure 1 Typical 120 VAC Q LED II Normalized Light Output vs Input Voltage Figure 2 Typical 120 VAC Q LED II Input Current vs Input Voltage...

Страница 10: ...olt circle equally spaced at 90 degrees Size w o connector 7 61in 193 4mm H x 2 50in 63 5mm W x 2 50in 63 5mm D Window Flat port 4 4 ENVIRONMENTAL Weight in Air 3 65 lb 1 66 kg Weight in Water 1 93 lb...

Страница 11: ...1 Load 2 Neutral 3 Earth Ground 04 XSG 3BCL HP SS ROS 60 01122 4 1 Earth Ground 2 Load 3 Neutral 05 LPBH 3 MP ROS 60 01010 4 1 Load 2 Neutral 3 Earth Ground 06 BH 3 MP W LOCK SLEEVE ROS 60 04080 4 1...

Страница 12: ...nt to the mating connector and carefully attach it to the bulkhead connector 4 Apply 120VAC 50 60Hz power and observe the lamp emit light 5 If you notice any issues with the functionality of the light...

Страница 13: ...s are available for purchase ROS P N 70 08251 01 and allow the light to easily be oriented in any direction 7 3 INTERCONNECTION Interconnection is made via the underwater connector To mate the connect...

Отзывы: