background image

10-00328   REV C 

 
 
 
 
 
 
 
 

DIMMABLE SOLID STATE 

UNDERWATER LED LAMP 

 

Q-LED II 

120VAC/160VDC 

 
 
 
 

OPERATING AND MAINTENANCE MANUAL 

 
 

 

 

 

SERIAL NUMBER: 

__________ 

 
 

 

 

SALES ORDER:  

__________ 

 
 
 
 
 
 
 
 
 

 
 

 

5618 Copley Drive 

San Diego, CA   92111-7902 

TEL: (858) 565-8500 

FAX: (858) 565-8808 

www.rosys.com

 

Содержание Q-LED II

Страница 1: ...OLID STATE UNDERWATER LED LAMP Q LED II 120VAC 160VDC OPERATING AND MAINTENANCE MANUAL SERIAL NUMBER __________ SALES ORDER __________ 5618 Copley Drive San Diego CA 92111 7902 TEL 858 565 8500 FAX 85...

Страница 2: ...is warranty shall be governed by the laws of the State of California In the event the defect is determined to be within the terms of this warranty then ROS agrees to repair and or replace at ROS s dis...

Страница 3: ...and are able to provide assistance during installation and or operation of these products If you have any questions or problems with this product that are not covered by this manual or instruction pl...

Страница 4: ...ATION 3 3 1 POWER 3 3 2 TEMPERATURE PROTECTION 3 3 3 RECOMMENDED OPERATION 3 4 SPECIFICATIONS 3 4 1 ELECTRICAL 3 4 2 PERFORMANCE 4 4 3 MECHANICAL 6 4 4 ENVIRONMENTAL 6 5 VIDEO COMPATIBILITY 6 6 CONNEC...

Страница 5: ...e Q LED II Like a conventional lamp light dimming is achieved by decreasing or increasing the input source voltage Lights powered by AC voltage can be dimmed using an AC phase control dimmer If powere...

Страница 6: ...a solid state LED light array The LED light engine is secured in the housing via a special assembly The forward end of the Q LED II is sealed with an o ring between the housing and a deepwater rated w...

Страница 7: ...t off switch The light will run for approximately 4 minutes in air at an ambient temperature of 20 C 68 F before automatically powering down There is no reset the light will automatically re illuminat...

Страница 8: ...original maximum output Dimming AC Powered Light is dimmed via input voltage or AC phase control DC Powered Light is dimmed via input voltage or PWM A modulation frequency of 1 kHz or higher is recom...

Страница 9: ...10 00328 REV C 5 Figure 1 Typical 120 VAC Q LED II Normalized Light Output vs Input Voltage Figure 2 Typical 120 VAC Q LED II Input Current vs Input Voltage...

Страница 10: ...olt circle equally spaced at 90 degrees Size w o connector 7 61in 193 4mm H x 2 50in 63 5mm W x 2 50in 63 5mm D Window Flat port 4 4 ENVIRONMENTAL Weight in Air 3 65 lb 1 66 kg Weight in Water 1 93 lb...

Страница 11: ...1 Load 2 Neutral 3 Earth Ground 04 XSG 3BCL HP SS ROS 60 01122 4 1 Earth Ground 2 Load 3 Neutral 05 LPBH 3 MP ROS 60 01010 4 1 Load 2 Neutral 3 Earth Ground 06 BH 3 MP W LOCK SLEEVE ROS 60 04080 4 1...

Страница 12: ...nt to the mating connector and carefully attach it to the bulkhead connector 4 Apply 120VAC 50 60Hz power and observe the lamp emit light 5 If you notice any issues with the functionality of the light...

Страница 13: ...s are available for purchase ROS P N 70 08251 01 and allow the light to easily be oriented in any direction 7 3 INTERCONNECTION Interconnection is made via the underwater connector To mate the connect...

Отзывы: