Galaxy Raid Installation and Hardware Reference Manual
5-12
Cooling Module Maintenance
Figure 5-16: Installing the new PSU Module
Step 9.
Secure the PSU to the subsystem
by inserting the retention screw
to the PSU. (See
Figure 5-17
)
Figure 5-17: Fastening the PSU Retention Screw
Step 10.
Replace the power cable that connects the PSU module to the
main power source.
Step 11.
Turn the PSU module on.
5.6. Cooling Module Maintenance
5.6.1 Cooling Module Overview
•
Cooling Module Overview
Redundant cooling modules:
The
GALAXY is equipped with two (2) redundant, hot-swappable, dual-
blower cooling modules located on the lower level of the subsystem
rear panel. These cooling modules control the internal operational
temperature of the subsystem and therefore their working integrity
should be maintained at all times.
•
Detecting a failed cooling module:
If a cooling module fails, the LED
located at the back of the module, an audible alarm, the firmware, the
RAIDWatch panel view, or the Configuration Client can notify you.