Controller functions
Version 1
RES-406
Page 35
13/
14
Temperature
coefficient
(as of Feb. 2006 and
GSD Version v2.0)
1100
ppm
400…4000
ppm
15
Temperature range
(as of Feb. 2006 and
GSD Version v2.0)
300°
C
200, 300,
400, 500°C
16/
17
Maximum
temperature
(as of Feb. 2006 and
GSD Version v2.0)
300°
C
200…500°
C
18
Temperature
diagnosis
(as of Feb. 2006 and
GSD Version v2.0)
de-
acti-
vated
deactivated,
activated
19
Temperature diag-
nosis delay time
(100ms steps)
(as of Feb. 2006 and
GSD Version v2.0)
0s
0…99
(0…9.9s)
20/
21
Heatup timeout
(100ms steps)
(as of Feb. 2006 and
GSD Version v2.0)
0s
0…999
(0…99.9s)
22
AUTOCOMP
(as of Feb. 2006 and
GSD Version v2.0)
off
off,
on,
AUTO
23
„TO“ bit
(Temperatur OK)
(as of Feb. 2006 and
GSD Version v2.0)
active
if
Tact
=
Tset
off,
active if
Tact=Tset,
active if
Tact=Tset
with latch
24
Hold mode
(as of Feb. 2006 and
GSD Version v2.0)
off
off,
on,
2s
1. The default value is stored in the device
master file and transferred from the
PROFIBUS master to the RES-406 when the
system is started up.
No.
Function
De-
fault
value
1
Possible
values