Replacing RES-222/RES-440

Old setting ranges on the RES-222:

New setting ranges on the RES-440:

The table below compares the two controllers.
These settings can be taken as a guide (e.g. when
the controller is started up for the first time):

5. Install the RES-440 controller in place of the

RES-222. The terminals of the two controllers are
identical. The existing connector plug-in parts can
be used without rewiring.

6. Switch on the line voltage.
7. A power-up message appears on the display when

the controller is switched on to indicate that it has
been started up correctly.

8. One of the following states then appears:

9. Select the language and reset the controller to the

factory settings.
Press the 

 key for at least 2s (to open the

Configuration menu). Step 20 is displayed. Select
the desired language with the 

 keys.

Confirm your selection by pressing 

. Press the

 key to display step 21 (factory settings). Press

the 

 key to confirm the factory settings (an

acknowledgment message appears). Step 22 is
displayed next.

10.Set the temperature range to 500°C

(Only if you have so far been using an

RES-222-0-5 controller)

Then set "Alloy 20, max 500°C" with the 
keys in step 22. Confirm your selection by pressing

.

11.Set the function of relay K1

Press the 

 key repeatedly until step 29 is

displayed. Select "Relay K1 active if Tact = Tset"
with the 

 keys. Confirm your selection by

pressing 

. Press the 

 key for at least 2s (to

return to the main or Alarm menu).

12.Calibrate the zero point

Activate the AUTOCAL function while the
heatsealing band is still cold.
Press the 

 key repeatedly until step 7 is

displayed. Then select the AUTOCAL function by
pressing the 

 key. If this function is executed

correctly, the main menu is displayed again
automatically.
If the zero has not been calibrated successfully, an
error message appears on the display. In this case
the controller configuration is incorrect (

ª

see

section „Controller configuration“ of the RES-440
documentation and the ROPEX Application Report).
Configure the controller correctly and repeat the
AUTOCAL function.

RES-222

RES-440

DIP switch 

ON

 

U

2

 

1

1

2

2

3

3

4

3

I

2

 

5

4

1 2 3 4 5

ON

1

2

3

4

5

Switch

No.

20-60

3- 10 8- 30

50-80

U

2

V

(  )

U   (  V )

2

I

2

 ( A )

1-10 6-60 20-120

30 - 100

60 - 200

120 - 400

OFF

OFF

OFF

ON

ON

ON

DIP-SWITCH

ON

1

2

3

4

5

1 2 3 4 5

ON

DISPLAY

ACTION

Main menu
Shows the SET and ACTUAL 
temperatures or the dynamic bar

Go to 9

Shows error code 104, 106, 109 
or 211

Go to 9

Shows error code 101…103, 
201…203, 801 or 9xx

Fault diagnosis
(

ª

RES-440

documentation)

ENTER

HAND

RESET

ENTER

HAND

RESET

ENTER

HAND

RESET

ENTER

HAND

RESET

ENTER

HAND

RESET

Содержание RESISTRON RES-222

Страница 1: ... are described below In addition the differences between the controller types are explained These instructions provide only a brief overview of the two controllers If in doubt please refer to the latest version of the controller documentation which is always binding Comparison of RES 222 RES 440 Dimensions The front panel cutout dimensions of the RES 222 and RES 440 controllers are identical The R...

Страница 2: ...entiometer the pointer of the indicating instrument must be set to Z RES 440 Automatic zero calibration AUTOCAL with step 7 in the software menu RES 222 Indicated by means of a red ALARM LED on the front panel Reset by pressing the RESET key RES 440 Indicated on the display The error is identified by a numeric code ª RES 440 documentation Reset by pressing the RESET key ENTER HAND RESET RES 222 Se...

Страница 3: ...h off the line voltage and verify the safe isolation from the supply 2 Remove the existing RES 222 controller 3 The supply voltage specified on the nameplate of the RES 440 controller must be identical to the line voltage that is present in the plant or machine The line frequency is automatically detected by the temperature controller in the range from 47 to 63Hz 4 Set the DIP switches on the RES ...

Страница 4: ...on by pressing 11 Set the function of relay K1 Press the key repeatedly until step 29 is displayed Select Relay K1 active if Tact Tset with the keys Confirm your selection by pressing Press the key for at least 2s to return to the main or Alarm menu 12 Calibrate the zero point Activate the AUTOCAL function while the heatsealing band is still cold Press the key repeatedly until step 7 is displayed ...

Страница 5: ...Press the key for at least 2s to open the Configuration menu Step 20 is displayed Press the key repeatedly until step 24 is displayed Select the low switching threshold Set point reached with the keys Confirm your selection by pressing 15 Press the key once Step 25 is displayed Select the high switching threshold Set point exceeded with the keys Confirm your selection by pressing Press the key for...

Страница 6: ... 3 Starting delay 2 Preheating temp Main menu Power up message 25 Set point exceeded 26 Time control 27 Cooling mode 29 Relay K1 function 30 Cycles 31 Alarm relay 32 Meas impulse 24 Set point reached 23 Max temperature Settings Configuration 1 2 1 Time control ON 2 Time control OFF 1 2 28 Start of sealing time Fault MOD 1 only Autocal 7 Autocal The relevant menu steps are shown on a gray backgroun...

Отзывы: