Replacing RES-222/RES-440

Set point selection

Zero calibration

Alarm output / reset

Manual mode

RES-222

 

Selection by means of a 10-turn potentiometer with 
a fine control knob.

RES-440

 

Selection with step 1 in the software menu. If the 
controller is active, the set point is also indicated on 
the display.

RES-222

 

Zero calibration by means of a 10-turn potentiometer 
(the pointer of the indicating instrument must be set 
to "Z").

RES-440

 

Automatic zero calibration (AUTOCAL) with step 7 in 
the software menu.

RES-222

 

Indicated by means of a red ALARM LED on the 
front panel. Reset by pressing the RESET key.

RES-440

 

Indicated on the display. The error is identified by a 
numeric code (

ª

RES-440 documentation). Reset 

by pressing the RESET key (

).

ENTER

HAND

RESET

RES-222

 

Selected by pressing the HAND key. The red ON 
LED is lit continuously.

RES-440

 

Selected by pressing the HAND key (

) while the 

main menu is displayed.

ENTER

HAND

RESET

Содержание RESISTRON RES-222

Страница 1: ... are described below In addition the differences between the controller types are explained These instructions provide only a brief overview of the two controllers If in doubt please refer to the latest version of the controller documentation which is always binding Comparison of RES 222 RES 440 Dimensions The front panel cutout dimensions of the RES 222 and RES 440 controllers are identical The R...

Страница 2: ...entiometer the pointer of the indicating instrument must be set to Z RES 440 Automatic zero calibration AUTOCAL with step 7 in the software menu RES 222 Indicated by means of a red ALARM LED on the front panel Reset by pressing the RESET key RES 440 Indicated on the display The error is identified by a numeric code ª RES 440 documentation Reset by pressing the RESET key ENTER HAND RESET RES 222 Se...

Страница 3: ...h off the line voltage and verify the safe isolation from the supply 2 Remove the existing RES 222 controller 3 The supply voltage specified on the nameplate of the RES 440 controller must be identical to the line voltage that is present in the plant or machine The line frequency is automatically detected by the temperature controller in the range from 47 to 63Hz 4 Set the DIP switches on the RES ...

Страница 4: ...on by pressing 11 Set the function of relay K1 Press the key repeatedly until step 29 is displayed Select Relay K1 active if Tact Tset with the keys Confirm your selection by pressing Press the key for at least 2s to return to the main or Alarm menu 12 Calibrate the zero point Activate the AUTOCAL function while the heatsealing band is still cold Press the key repeatedly until step 7 is displayed ...

Страница 5: ...Press the key for at least 2s to open the Configuration menu Step 20 is displayed Press the key repeatedly until step 24 is displayed Select the low switching threshold Set point reached with the keys Confirm your selection by pressing 15 Press the key once Step 25 is displayed Select the high switching threshold Set point exceeded with the keys Confirm your selection by pressing Press the key for...

Страница 6: ... 3 Starting delay 2 Preheating temp Main menu Power up message 25 Set point exceeded 26 Time control 27 Cooling mode 29 Relay K1 function 30 Cycles 31 Alarm relay 32 Meas impulse 24 Set point reached 23 Max temperature Settings Configuration 1 2 1 Time control ON 2 Time control OFF 1 2 28 Start of sealing time Fault MOD 1 only Autocal 7 Autocal The relevant menu steps are shown on a gray backgroun...

Отзывы: