Technical data
RES-445
Page 9
6
Technical data
Type of construction
Housing for front panel mounting
Dimensions (W x H): 144 x 72mm; depth: 161mm (incl. terminals)
Line voltage
All controllers manufactured as of January 2004:
115VAC version: 115VAC -15%…10% (equivalent to 98…132VAC)
230VAC version: 230VAC -15%…10% (equivalent to 196…264VAC)
400VAC version: 400VAC -15%…10% (equivalent to 340…456VAC)
All controllers manufactured up to December 2003:
115VAC, 230VAC or 400VAC, tolerance: +10% / -15%
depending on device version (
!
Kap. 13 „How to order“ auf Seite 54)
Line frequency
47…63Hz, automatic adjustment to frequencies in this range
Heatsealing band
type and temperature
range
Several different ranges can be selected on the controller in the Configuration
menu:
Temperature coefficient 410ppm, 0…300°C (SW revision 021 or higher)
Temperature coefficient 460ppm, 0…300°C (SW revision 019 or higher)
Temperature coefficient 510ppm, 0…300°C (SW revision 019 or higher)
Temperature coefficient 570ppm, 0…300°C (SW revision 019 or higher)
Temperature coefficient 630ppm, 0…300°C (SW revision 019 or higher)
Temperature coefficient 700ppm, 0…300°C (SW revision 019 or higher)
Temperature coefficient 780ppm (e.g. Alloy L)
0…200°C, 0…300°C, 0…400°C, 0…500°C
(SW revision 011 or higher)
Temperature coefficient 870ppm, 0…300°C (SW revision 019 or higher)
Temperature coefficient 980ppm, 0…300°C (SW revision 019 or higher)
Temperature coefficient 1100ppm (e.g. Alloy 20):
0…200°C, 0…300°C, 0…400°C, 0…500°C
Temperature coefficient 3500ppm (e.g. NOREX:
0…200°C, 0…300°C
Set point selection/
analog input
Terminals 20+23
Via the Settings menu in the controller or the electrically isolated analog input:
Input resistance: 40kohms, reverse polarity-protected
0…10VDC, equivalent to 0…300°C or 0…500°C
Analog output
(actual value)
Terminals 20+24
0…10VDC, Imax = 5mA
Equivalent to 0…300°C or 0…500°C
Electrically isolated
Digital logic levels
Terminals 3, 4, 22, 25,
26
LOW (0V): 0…2VDC
HIGH (24VDC): 12…30VDC (max. current input 6mA)
Electrically isolated, reverse polarity-protected
START with contact
Terminals 2+7
Switching threshold: 3.5VDC, U
max
= 5VDC, I
max
= 5mA
Switching output
for "Temp. OK" signal
Terminals 20+21
U
max
= 30VDC, I
max
= 50mA
U
ON
< 2V (saturation voltage)
Transistor conductive if the temperature is inside the tolerance band.
Alarm relay
Terminals 5+6
Contact, potential-free, U
max
= 50VDC, I
max
= 0.2A