Technical data
Page 8
RES-430
6
Technical data
Type of construction
RES-430 motherboard with power section:
Open design for installation in the machine frame
Dimensions (L x W): 210 x 110mm, height: 45mm (incl. terminals)
T-430 display terminal:
For installation in the machine frame
Dimensions (W x H): 144 x 72mm; depth: 66mm (incl. connecting cables)
Line voltage
115VAC, 230VAC, tolerance: +10% / -15%
depending on device version (
ª
section 13 „How to order“ on page 48)
Line frequency
47…63Hz, automatic adjustment to frequencies in this range
Heatsealing band
type and temperature
range
Several different ranges can be selected on the controller in the
Configuration menu:
Default: Temperature coefficient 1100ppm (Alloy 20), 0…300°C
Heatsealing band
voltage
(secondary voltage of
impulse transformer)
12…42VAC
Max. load current
(max. secondary
current of impulse
transformer)
Terminals 5, 6, 7, 8
Two heatsealing bands:
I
sec max
= 90A (per heatsealing band: I
max
= 45A)
One heatsealing band:
I
sec max
= 70A
If only one heatsealing band is used, terminals 7+8
must be externally jumpered with a high current cable in order to
avoid malfunctions or damage to the controller.
Min. load current
Up to SW revision 007:
I
sec min
= 30A
SW revision 008 or higher:
I
sec min
= 20A
Analog output
(actual value)
Terminals 10+11
0…10V DC, Imax = 5mA
Equivalent to 0…300°C or 0…500°C
START with contact
Terminals 12+14
Switching threshold: 3.5VDC, U
max
= 5VDC, I
max
= 5mA
FOOT SWITCH
with contact
Terminals 12+13
Switching threshold: 3.5VDC, U
max
= 5VDC, I
max
= 5mA
Relay K1
Terminals 19, 20, 21
Changeover contact, potential-free, U
max
= 240VAC/100VDC, I
max
= 1.5A
Interference suppression with 47nF / 560ohms for each terminal
Solenoid drive output
(optional, instead of
K1)
Terminals 15, 16, 17,
18
U
max
= 30VAC (supply voltage at terminals 17+18)
I
max
= 2A
Load cell interface
Terminals 22, 23, 24,
25
For load cells with 2mV/V, R
min
= 165ohms
Supply voltage (terminals 22+25): U
VCC
= 5VDC
!