When installing the frame into a WC furniture unit, some struts may need to be removed. Always check before cutting that
the unit integrity will not be compromised. Units can be screwed to adjoining units in a run where possible to add further
strength.
Front struts in a WC furniture unit will cause the frame to be spaced away from the main WC facing fascia of a WC unit.
This will create a void which will need to be filled (between the frame and the back of the main fascia) to stop the main
fascia bowing in when the WC is in use.
You may need to remove the feet in a fitted furniture WC Unit to facilitate room for the frame. The unit can be wall hung
instead.
Any back rails in a WC Unit must be removed or repositioned to the back of the unit if they are not already. Frame brackets
must screw directly into a solid wall. Screwing into a rail or strut that is not secured up against a solid wall will not prove
strong enough when the frame is in use.
Wall plugs supplied are ONLY suitable for solid stone/brick walls. They are not suitable for use in aerated blocks or similar.
If fixing to a stud wall, sufficient extra internal reinforcements must be made to the wall. Screws must locate into suitably
reinforced studs and noggins.
Take care using power tools – The use of a residual current device (RCD) is recommended. Beware of hidden cables or
pipes when drilling.
This product can be dangerous if installed incorrectly. This product must be installed by a qualified plumber or installer. It
is the installer’s responsibility to check that the fixings are suitable for the installation in hand.
Cistern fittings are suitable for Water pressure: 0.2 - 10 bar. Do not add caustic chemical substances (eg containing
chlorine compounds or similar) into the cistern. These can damage the valve components and cause failure.
Before starting to enclose the frame, the system must be first tested for leaks before 2nd fix commences. Using the help
of a second person to hold the pan in place on the frame, turn on the water supply and flush the pan to check for leaks.
general care & safety
using the frame in a furniture unit
820mm wall hung frame
fitting instructions
Square flanged
elbow fitting F 1/2"
Fill valve
Stop valve
Cistern plate
Protective case
Flush valve
Frame
Wall Bracket x4
Fixing Bolts, Washers and Plugs x 4
8x M8 x 25mm
Bolts & Washers
(Secure brackets /
plates to frame)
Flat Plate x2
Floor fixing screws x 2
Pan Connector kit
Flexible pipe
Inlet pipe
Waste pipe kit
Adjustable foot x2
110mm waste adaptor
Inlet pipe bung
Waste pipe bung
Flexible
sheath(x2)
Air hose pipe
Please read completely first before commencing.
Please retain for future reference.
This product must be installed by a qualified fitter or plumber in accordance with and meet the requirements of
the Water Supply (Water Fittings) Regulations 1999 and Scottish Byelaws 2004
exploded diagram
15
EN 14055:2010 &
EN 14124: 2004
Load Tested to EN 997: 400KG
1
TR9005
V4.PL.13.08.18015