background image

Please retain for future reference. Instructions should be kept / passed to end-user once installation is complete.

INSTALLATION & AFTERCARE INSTRUCTIONS

MIRROR PRODUCT INSTRUCTIONS

FRAME MIRRORS

ELECTRICAL SAFETY INSTRUCTIONS

All fittings must be installed by a competent person, in accordance with current IEE wiring 
regulations. If in doubt consult a qualified electrician.

IMPORTANT

Always switch off the electrical supply at the mains during installation and maintenance. It is 
recommended that the fuse is withdrawn or the circuit breaker is switched off for the necessary 
circuit before installation commences.

The product must be installed with a minimum distance of 150mm between the infrared sensor 
and any adjacent wall or obstruction to ensure correct function of the sensor.

Fitting in bathrooms is subject to the appropriate zone in accordance with IEE Regulations. This 
product is suitable for zone 2 and outside zones. It is NOT suitable for installation in Zone 0 or 
Zone 1. It is also not suitable for installation in saunas, steam rooms or shower cubicles. This 
product is only suitable for permanent installation. Do NOT connect to a trailing plug and socket 
outlet. Although this product has an Ingress Protection rating of IP44 it is only suitable for indoor 
use. Do not attach the product to surfaces that are damp or otherwise electrically conductive.

INSTALLATION CARE & SAFETY

Wear suitable eye protection when drilling. Take care when using power tools near water - the use 
of a residual current device (RCD) is advised. Beware of hidden cables or pipes. Take care if 
drilling on tiled surfaces in case the drill slips. A piece of masking tape applied to the wall before 
marking out the fixing holes will stop the drill from wandering.

Do NOT strike glass components with hard or pointed items. Do NOT place very hot or very cold 
items against or in close proximity to glass surfaces unless an adequately thick insulation material 
is used to prevent such items coming in contact with the glass.  

The nominal thickness of the mirror glass used in this product is 5mm and is film backed for 
safety. If the glass becomes chipped or broken replace immediately.

This product should be positioned well away from curtains and other fabrics. Never cover the 
mirror. This product is heated, we recommend that it is turned off after use and should never be 
left on for prolonged periods of time 

This product should only to be installed by a competent person.

CLEANING

It is recommended that the unit is cleaned with a soft, dry, non abrasive cloth when turned off.  
Never use cleaning agents or abrasive materials on any type of surface finish.  Do not allow 
moisture to come into contact with the electrical components.

COMPLIANCE

This product complies with all relevant British 
and European safety standards.

2

2

2

OUTSIDE

ZONES

2

ZONE

1

0.75m

2.25m

3.0m

0.6m

0.6m

0.75m

BATHROOM ZONES DIAGRAM

Distances from a bath tub or shower tray

FR60RW & FR60RG

FR60SW & FR60SG

FR80RW & FR80RG

AO.11.18.V1

Strip wires to a suitable
length. DO NOT connect
to a plug & socket outlet.

THIS PRODUCT IS MANUFACTURED TO CLASS I

CATEGORY AND MUST HAVE AN EARTH CONNECTION.

! IF IN DOUBT CONSULT YOUR ELECTRICIAN !

COLOUR CODING:

L  -  Live 

= Brown

N  -  Neutral  = Blue
 

-  Earth  = Green & Yellow

FR120SW & FR120SG

FR60RW, FR60RG, FR60SW, FR60SG
FR80RW, FR80RG, FR120SW, FR120SG

-

Отзывы: