ROOTS RootsSweep B70 Скачать руководство пользователя страница 16

16

RootsSweep B70

1

1.  Charger cable
2.  On-board charger
3. Operating panel
4.  Battery

2

Charging battery

Before starting the machine up for the first time, 
the  battery  to  be  used  must  be  fully  charged, 
properly,  by  implementing  the  initial  battery 
charge  routine.  Roots  assumes  no  liability  for 
damage to the battery caused by a fault when the 
battery is charged for the first time.

During operation, the battery discharge indicator in the 
operating  panel  indicates  the  discharge  status  of  the 
battery. The battery must be charged immediately the 
red LED lights up. The battery is recharged using the 
integrated on-board charger.

Ÿ

Set the key switch to Position 0.

The battery should not be charged in 
Position 1.

Ÿ

Remove the charger cable from the recess on the 
right-hand side of the machine.

Ÿ

Plug the charger cable in a 230 V power outlet.

While  the  battery  is  charging,  the  charge  control 
indicator lights up in the operating panel.

W h e n   t h e   c h a r g i n g   p r o c e s s   h a s   b e e n 
completed, disconnect the plug from the power 
outlet and return safely to the recess.

The  battery  must  be  kept  clean  and  dry  to  prevent 
creeping  current.  Clean  the  battery  according  to  the 
instructions”Cleaning batteries“. Any liquid in the battery 
container must be extracted and disposed of according 
to regulations.

5. Care

Maintenance to be carried out every three months After 
fully  recharging  and  following  a  standing  period  of  at 
least  5  hours,  the  following  must  be  measured  and 
recorded:

Ÿ

Total voltage

Ÿ

Individual voltage

If  noticeable  changes  are  detected  compared  to 
previous  measurements,  or  differences  between  the 
cells or block batteries, the customer service should be 
called for testing or repair.

Before starting any maintenance and repair work, 
set the key switch to Position 0 to prevent starting 
the machine inadvertently!

Batteries may only be handled and changed by 
properly skilled maintenance personnel.
Only batteries approved by Roots may be used.

6. Storage

If batteries are out of operation for longer periods, they 
should be stored in fully charged state in a dry, frost free 
room.

Ÿ

In  order  to  ensure  that  the  battery  is  ready  for  

operation at any time, it can be recharged according 
to one of the following methods

Ÿ

Full  recharge  every  three  months.  When  a 

consumer  is  connected  up  (e.g.  measuring  or 
controlling  devices),  it  may  be  necessary  to 
recharge the battery every two weeks.

The  customer  service  should  be  called  immediately 
when  any  faults  are  discovered  in  battery  or  battery 
charger. 

7. Faults

Disposal of Batteries

Old batteries with this sign are recyclable 

economic goods and should be brought 
back into the recycling process.

Old  batteries  which  are  not  brought  back  into  the 
recycling process, have to be dealt with as dangerous 
materials under the observance of all regulations.

BATTERY INSTRUCTIONS

3

RootsSweep B70

+

-

0

I

4

Содержание RootsSweep B70

Страница 1: ...1 RootsSweep B70 Owner s Manual RootsSweep B70 Walk Behind Floor Carpet Sweeper Battery Read this manual completely and understand the instructionsbeforeoperatingthemachine EnglishVersion 24V...

Страница 2: ...2 RootsSweep B70...

Страница 3: ...00 Rev E 10 17 Prepared by SN NPM TD Dept TECHNICAL SPECIFICATION Technical Specification Introduction General safety instructions First operation Machine operation Battery instructions Maintenance se...

Страница 4: ...turer cannot be held liable for consequential damages The terms of proper use also includes compliance with the manufacturer s instructions on the operation maintenance and repair of the product This...

Страница 5: ...hing on the rotary broom otherwise imprints of the broom could be produced on the floor Never leave the machine unattended as long as the motor is running Suitable tools must be used for cleaning and...

Страница 6: ...loorings and for operation on level grounds with a maximum inclination of up to 2 This machine is not intended for use on public roads and places Only qualified personnel must perform maintenance and...

Страница 7: ...f the handlebar Before starting up for the first time connect the positive cable of the device as illustrated to the positive pole of the battery in the device Connecting the battery Before starting u...

Страница 8: ...y broom sweeps the dirt into the dirt hopper using the overhead throw method The particulate matter is forced against the panel air filter by the suction turbine and filtered out there Only dust free...

Страница 9: ...ents with liquids Risk of electric shock It is not permitted to clean the machine with a pressure washer or steam cleaner Operating the shaking device Only operate the shaking device when the motor is...

Страница 10: ...worn distance between wheel and running surface 1mm Loosen the screw connection in the friction wheel crank Tension the belt which leads to the rear wheel shaft by moving the friction wheel crank in t...

Страница 11: ...bolts washers and hexagon nuts to the side broom holder Assemble the plastic housing and fix it in place with the screws Main Rotary Broom Before starting any maintenance and repair work set the key s...

Страница 12: ...e machine back up again Install the battery again in the machine After changing the rotary broom readjust the sweeping pattern as necessary Setting the sweeping pattern In the case of broom wear and a...

Страница 13: ...andlebar forwards The hopper link assembly handle pull shifted The motor should have come to a standstill before the dirt hopper is removed Risk of injury through swirling waste and dust Hold the dirt...

Страница 14: ...bled Assemble the new sealing strips Inserting panel air filters Insert the thoroughly cleaned or new panel air filter from the correct side in the filter support frame Pay attention to the labeling o...

Страница 15: ...ctions e g plugs may be connected or disconnected only when the machine is in off condition Discharge batteries must be recharged immediately and may not remain in discharged condition this also appli...

Страница 16: ...ed out every three months After fully recharging and following a standing period of at least 5 hours the following must be measured and recorded Total voltage Individual voltage If noticeable changes...

Страница 17: ...ecial maintenance free batteries approved by Roots may be installed at the prescribed position Ensure the motor has stopped before opening the hood Risk of injury through belt drive and rotating fan T...

Страница 18: ...ined personnel and genuine Roots spare parts are at your disposal In case of any inquiries or orders for spare parts please always quote the machine s serial number mentioned on the nameplate The name...

Страница 19: ...ve cable and front apron lifting cable Lift the main and side broom while transporting the machine Use the front apron lifting mechanism to collect any bigger debris Bypass the vacuum if the floor is...

Страница 20: ...20 RootsSweep B70...

Страница 21: ...21 RootsSweep B70 Roots Multiclean Ltd R K G Industrial Estate Ganapathy Coimbatore 641 006 India Phone 91 422 4330 330 E mail rmclsales rootsemail com Web rootsmulticlean in Toll Free 1800 41 99 77 9...