Lead Acid (LA) Battery Instructions
7. Storage-
If batteries are out of operation for longer periods, they
should be stored in fully charged state in a dry, frost free
room.
In order to ensure that the battery is ready for operation at
any time, it can be recharged according to one of the
following methods:
1. Full recharge every three months. When a consumer is
connected up (e.g. measuring or controlling devices), it may
be necessary to recharge the battery every two weeks.
2. Maintenance recharging at a recharging voltage of 2.25 V
x number of cells. The storage period is to be taken into
account for the service life.
8. Faults-
The customer service should be called immediately when
any faults are discovered in battery or battery charger.
Ÿ
Kindly ensure that the Warranty certificate of the
battery is available at your end.
Ÿ
Kindly read the Do’s & Don't’s of the battery,
understand and follow.
Ÿ
Check the electrolyte level before charging and top it
up with battery grade distilled water if required.
Ÿ
Match the battery to the correct charger.
Ÿ
Keep the battery well ventilated while charging.
Ÿ
Charge the battery immediately after it is discharged
completely.
Ÿ
Keep all inter cell connections and bolted terminals
tight and covered with petroleum jelly.
21
RootsScrub RB 800 C
Disposal of batteries
Battery connection diagram
Battery and charger specification
Old batteries with this sign are recyclable economic goods
and should be brought back into the recycling process.
Old batteries which are not brought back into the recycling
process, have to be dealt with as dangerous materials under
the observance of all regulations.
Battery:
Type: Traction block battery
Rating: 24V, DC, 320Ah
Charger:
Type: Off-board
Rating: 230V, AC, 50-60Hz, 30Amps
BATTERY SYSTEM