PROCEDURE FOR SCRUBBING

At the end of cleaning 

Ÿ

Stop the machine and lift the brush head.

Ÿ

Lift the squeegee.

Ÿ

Drain and rinse the dirty water tank (refer to section 

"Dirty and Fresh Water Tanks" )

Ÿ

Clean the sealing strips at the squeegee.

Ÿ

Check the strainer upstream of the intake opening in 

the fresh water tank; clean if required,   as otherwise 
the suction efficiency will be affected.

The machine must not be cleaned by water jet or 
h i g h   p r e s s u r e   c l e a n i n g   e q u i p m e n t , 
as this will endanger its proper working function.

Remove  the  Hose 
from  this  clamp  to 
drain the water

Draining of Dirty water tank

 When work is completed, the dirty water tank 
has to be drained  and rinsed. 

Ÿ

The hose used to drain the dirty  water.

Draining of Fresh water tank

The tank requires rinsing at regular intervals.

Ÿ

The water level hose is used to drain the fresh  water.

Procedure for draining tanks  

Ÿ

Unclamp the drain hose from the hose clamp.

Ÿ

Lower the tip of the drain hose to the floor level

Ÿ

After draining the water completely, clamp the hose 
in the hose clamp.

Содержание RootsScrub B4550C

Страница 1: ...ootsScrub B4550C RootsScrub B4550C B4550Cx Walk Behind Floor Scrubber Drier Electric Read this manual completely and understand the instructionsbeforeoperatingthemachine EnglishVersion Owner s Manual...

Страница 2: ...2 RootsScrub B4550C...

Страница 3: ...is manual Roots Multiclean Ltd RKG Industrial Estate Coimbatore 641 006 India 557350118 00 Rev D 09 17 Prepared by KM NPM TD Dept Description Page No Introduction Know Your Machine Technical Specifica...

Страница 4: ...roduct sold within India If the product requires repair or maintenance work to be performed please ensure that you get the machine serviced from an authorised service center or dealer of RMCL to ensur...

Страница 5: ...age m2 h 2000 2000 Working Speed up to km h 4 4 Battery Rating V Ah 12 96 Airflow rate L sec 28 28 Vacuum Pressure mm of H2O 1087 1087 Power Supply V 24 24 Total Power W 1000 1000 Brush Motor W 650 65...

Страница 6: ...cing operation Adherence to the above general instructions will help avoid the operator from having to read the manual while operating the machine Safety during machine operation The machine is applic...

Страница 7: ...tions Damaged parts may only be changed at an authorized service center It is not permitted to use aggressive and corrosive cleaning agents Used batteries with the recycling symbol must not be dispose...

Страница 8: ...also substantially reduced If floors are particularly dirty or if wax has to be removed basic cleaning the floor must be treated twice During the first cycle the floor is scrubbed with the cleaning a...

Страница 9: ...quipment and cause personal injury LEGEND DESCRIPTION PURPOSE A Main Power Switch Initiates power supply to the system B Brush Motor Switch For On Off C Suction Turbine For On Off Shows information so...

Страница 10: ...conds 5 Brush Motor Suction Turbine OFF The brush motor shuts down immediately when switch B 0016 10 BATTERY CHARGING 6 The brush motor suction turbine icons will start flashing just before the batter...

Страница 11: ...that the guiding rollers and the brushes catch safely When mounting check the safe catching of rollers and brushes Before cleaning or maintaining the machine as well as before replacing parts of it tu...

Страница 12: ...s 2 Mount the new sealing strips by inverse sequence of operation Removal of Squeegee 1 Squeegee 2 Squeegee Knob 3 Squeegee Bracket group Mounting of Squeegee first time Lift squeegee bracket group 3...

Страница 13: ...preclude damages at the suction turbine We recommend our agents for cleaning and care which are perfectly adopted to the machine How to operate the machine Refer Controls section of B4550C B4550Cx in...

Страница 14: ...er jet or h i g h p r e s s u r e c l e a n i n g e q u i p m e n t as this will endanger its proper working function Remove the Hose from this clamp to drain the water Draining of Dirty water tank Wh...

Страница 15: ...ine at your disposal which is ready to work and in good operating condition Please contact your local Roots Multiclean distributor the people there will be glad to perform that work for you There well...

Страница 16: ...ry Replace battery Loose battery cable Tighten loose cable Main fuse blown Replace the fuse Main fuse blown Replace the fuse Faulty brush motor or loose cable Contact service Suction turbine does not...

Страница 17: ...ated area Make sure to connect the charger to the specified voltage and frequency Ensure that the seat cover is completely open Do not place any objects on the battery Electrolyte is highly corrosive...

Страница 18: ...rminals tight and covered with petroleum jelly Keep the machine tank opened while charging to improve ventilation Battery and Charger Batteries connecting diagram The batteries and charger are located...

Страница 19: ...harger manufacturer s user manual which is supplied along with the machine Disposal of Batteries Old batteries with this sign are recyclable economic goods and should be brought back into the recyclin...

Страница 20: ...20 RootsScrub B4550C NOTES...

Страница 21: ...21 RootsScrub B4550C...

Страница 22: ...RootsScrub B4550C Roots Multiclean Ltd R K G Industrial Estate Ganapathy Coimbatore 641 006 India Phone 91 422 4330 330 E mail rmclsales rootsemail com Web rootsmulticlean in Toll Free 1800 41 99 77...

Отзывы: