background image

DC ARC WELDING INVERTER 

6

1.6

44~84

21.76~23.36

2.0

60~100

22.4~24.0

2.5

80~120

23.2~24.8

3.2

108~148

23.32~24.92

4.0

140~180

24.6~27.2

NOTE:

This table is suitable for mild steel welding. For other materials, consult 
related materials and welding process for reference.

WORKING ENVIRONMENT 

CAUTION:

1) Welding should be carried out in dry environment with humidity of 
90% or less.
2) The temperature of the working environment should be between -10c 
and 40c.
3) Avoid welding in the open air unless sheltered from sunlight and rain. 
Keep it dry at all times and do not place it on wet ground or in puddles.
4) Avoid welding in dusty area or environment with corrosive chemical 
gas.
5) Gas shielded arc welding should be operated in environment without 
strong airflow.

SAFETY TIPS 

Over-current/over-voltage/over-heating protection circuit is installed 
in this machine. When the network voltage, output current or inner 
temperature exceeds the set standard, the machine will stop 
automatically. However, excessive use (e.g. too high voltage) of machine 
will lead to welder damage. Therefore, please note:
2.1 Ventilation
This welder can create powerful cutting current that has strict cooling 
requirements that cannot be met with natural ventilation. Therefore the 

Содержание RH-4605

Страница 1: ...DC ARC WELDING INVERTER RH 4605...

Страница 2: ...lease refer to the operator safety guidelines in conformity with the accident prevention requirements of the manufacturer Professional training is needed before operating the machine Use labor protect...

Страница 3: ...on may cause fire or explosion Welding sparks may result in a fire so please make sure there are no combustible materials nearby and pay attention to fire hazard Have a fire extinguisher nearby and ha...

Страница 4: ...nd weight of the welder Great reduction in magnetic and resistance loss obviously enhances the welding efficiency and energy saving effect Switching frequency is beyond audio range which almost elimin...

Страница 5: ...IES 1 8 m welding holder 1 2m earth clamp Welding Mask Steel brush INSTALLATION DEBUGGING AND OPERATION NOTE Please install the machine strictly according to the following steps Turn off the power sup...

Страница 6: ...e while there is no special requirement for acid electrode 5 2 OPERATION METHOD 1 After being installed according to the above method and the power switch being switched on the machine is started with...

Страница 7: ...ain Keep it dry at all times and do not place it on wet ground or in puddles 4 Avoid welding in dusty area or environment with corrosive chemical gas 5 Gas shielded arc welding should be operated in e...

Страница 8: ...range In case that the input voltage exceeds the stipulated value it would possibly damage the components of the machine 2 4 An earth terminal is available for the machine Connect it with an earth cab...

Страница 9: ...en there are no abnormal phenomena anymore can the machine be used 5 Check periodically whether the insulation cover of all cables is in good condition If there is any dilapidation rewrap it or replac...

Страница 10: ...xists inside the machine Open circuit or loose contact occurs at the joint of output terminal The overheating LED is on The machine is under over heating protection status It can recover auto maticall...

Страница 11: ......

Страница 12: ......

Отзывы: