background image

USER MANUAL

5

vibraton or other defects are detectedhave it repaired.
Wear hearing protection while operating the power tools. The declared 
vibration total value has been measured in accordance with a standard 
test method and may be used for companing one tool with another.
The declared vibration total value may also be used in a preliminary 
assessment of exposure.

WARNING!

The vibration emission during actual use of the power tool can differ from 
the declared total value depending on the ways in which the tools is used.
There is the need to identify safety measures to protect the operator that are 
based on an estimation of exposure in the actual condition of use (taking 
account of all parts of the operating cycle such as the times when the tool 
is switched off and when it is running idle in addition to the trigger time).

ASSEMBLY

.

CHANGING THE TOOL

-Before any work on the power tool(e.g.maintenancetool change etc.)as 
well as during transport and storageset the rotational direction switch to 
the center position.unintentional actuation of the on/off switch can lead 
to injuries.
-The drill spindle is locked when the ON/OFF switch 5 is not pressed.
This makes quickconvenient and easy changing of the tool in the drill 
chuck possible.
-Open the keyless chuk by turning in rotation direction until the tool can 
be inserted.insert the tool. 
-Firmly tighten the collar of the keylees chuck by hand in rotation direction.

.

REPLACING THE DRILL CHUCK

Before any work on the power tool(e.g.maintenancetool change etc.)as 
well as during transport and storageset the rotational dircttion switch to 
the center position.unintentional of the on/off switch can lead to injuries.

Содержание 2513T

Страница 1: ...2513T ELECTRIC SCREW DRIVER DRILL ...

Страница 2: ... instructions failure to follow all warning and instruction may result in election shock fire and or serious injury Save all warning and instructions for future reference The term power tool in the warning refer to your mains operated corded power tool or battery operated cordless power tool WORK AREA Keep your work area clean and well lit Cluttered benches and dark areas invite accidents Do not o...

Страница 3: ... damaged or entangled cords increase the risk of electric shock when operating a power tool outdoors use an outdoor extension cord marked W A or W these cords are rated for outdoor use and reduce the risk of electric shock If operating a power tools in a damp location unavoidable use a residual current device RCD protected supply Use of an RCD reduces the risk of electric shock PERSONAL SAFETY Sta...

Страница 4: ...tool Use the correct power tool for your application The correct power tool will do the job better and safer at the rate for which it is designed Do not use the power tool if the switch does not turn it on and off Any power tool that cannot be controlled with the switch is dangerous and must be repaired Disconnect the plug from the power source before making any adjustments changing accessories or...

Страница 5: ...jury 3 Hold power tool by insulated gripping surfaces wrien performing an operation where the cutting accessory may contact hidden wiring or its cord Cutting accessory contacting a live wire may make exposed metal parts of the power tool live and could give the operator an electric shock ADDITIONAL SAFETY REGULATIONS WARNING Remove the plug from socket before carrying out any installationa adjustm...

Страница 6: ... times when the tool is switched off and when it is running idle in addition to the trigger time ASSEMBLY CHANGING THE TOOL Before any work on the power tool e g maintenancetool change etc as well as during transport and storageset the rotational direction switch to the center position unintentional actuation of the on off switch can lead to injuries The drill spindle is locked when the ON OFF swi...

Страница 7: ...htened with a tightening torque of approx 20Nm Screw the securing screw in counter lock wisw direction into the opened keyless chuck Tightening torque approx 4 5Nm Always use a new securing screw as the threads are covered with a thread locking compound that loses its effect after multiple usage DUST CHIP EXTRACTION Dusts from materials such as lead containing coatings some wood types minerals and...

Страница 8: ... F R lever is used to reverse the rotational of the machine However this is not possible with the on off switch Right rotation for drilling and deriving in screws push the F R lever left stop Left rotation for loosening and unscrewing screws and nuts press the F R lever through to the right stop SETTING THE TORQUE with the clutch cap the required torque setting can be preselected in 18 1 steps It ...

Страница 9: ...d in flush with the material and then release the on off switch By doing so the head of the screw does not penetrate into the material Working instructions Apply the power tool to the screw only it is switched off Rotating tool inserts can slip off TIPS After longer period of wording art law speed Allow the machine to down by running it for approx Minutes at maximum speed with no load For drilling...

Страница 10: ...physician and the medical implant manufacturer before operating this machine WARNING To ensure safety and reliability all repairs should be performed by an authorized servise center or other qualifiled service organization ENVIRONMENTAL PROTECTION AND GUARANTEE Waste electrical products should not be disposed of with household waste Pleas recycle where facilities exist check with your with your lo...

Страница 11: ...magnetic filed during operation this filed may under some circumstances interfere with active or passive medical implants to reduce the risk of serious or fatal injury we recommend persons with medical implants to consult their physician and the medical implant manufacturer before operating this machine ...

Страница 12: ......

Страница 13: ......

Отзывы: