12
A) The top of the chimney is resistant to wind
B) Chimney dimensions are not limited; important is that chimney does not have more then 15 Pa
draft
C) Gasket /Sealed
D) Inspection hole - for control
Flue pipes that are in poor shape, or are made out of inappropriate materials (asbestos cement,
galvanized sheet, etc. with rough or porous surfaces) are inadequate and jeopardize the proper
functioning of the boiler.
The smoke can be drained through a classic smoke pipe (see next Figure), provided that it meets the
following requirements:
- Check the maintenance of the drain flue pipes or chimneys. If the smoke drain pipe is old it should be
replaced with a new one. If the chimney is damaged it is good to repair it or rebuild it by inserting a steel
pipe that is properly insulated with mineral wool.
- The smoke can be discharged directly into the smoke pipe (chimney) only if it has a minimum draft of 5
Pa, and not bigger then allowed limit (15 Pa), and if there is a cover for checking and cleaning.
-
If the chimney draft is less then minimal needed (5 Pa)
,
or if draft is bigger then maximum
allowed (15 Pa),
possible increased regulation of draft (its decrease) in the chimney can be regulated ba
following ways:
1. If in the bottom of the chimney there is an opening for cleaning, on opening can be installed draft
regulator.
2. Insert a steel pipe in the chimney with a diameter of 12cm or more, if there is a possibility for such
reparation of the chimney.
3. Inspection of chimney by adequate chimney service and proposal solutions to problems from their part
4. By adjusting certain parameters in the stove. This adjustment must be done only by an authorized
service of Termal int.
- Make sure that the connection to home chimney is properly sealed.
- Avoid contact with material that burns easily (such as wooden beams), and in all cases they should be
isolated with anti-fire material.
A) Mineral wool
B) Steel pipes
C) A peripheral wall
The stove is designed to be connected to the chimney flue pipes with a diameter of 80mm. If you are not
using a standard chimney, but you have a new chimney, or you are modifying the existing one, use
insulated stainless pipes (double wall) with a diameter given in Table 1. Flexible pipes are not permitted.
Содержание SM ECO 25
Страница 7: ...7 Figure 1 Boiler SM ECO 33 compact ...
Страница 36: ...36 ...
Страница 37: ...37 Figure 28 Power Fan Temperature Fuel Time Settings ...
Страница 44: ...44 16 6 ELECTRICITY SCHEME Figure 30 Electricity scheme ...
Страница 47: ...47 ...
Страница 48: ...48 16 8 ALARMING SITUATION ...
Страница 49: ...49 ...
Страница 50: ...50 ...
Страница 51: ...51 ...