RS-500 WIC, RS-500M, and RS-600M Door Training Guide
Section 5: Program Parameters
Parameter
Definition
Default Value
P1
Close Time Delay (Seconds)
20
P3
Deceleration Range
0
P4
Warning Output Function
0 – Door Movement/About to Close
0 – Door Movement/About to Close
1 – Sequential Interlock
2 – Passive Interlock
3 – Door Open Indication
4 – Door Closed Indication
P7
Refresh Door Limits
25
P10
Service Cycle Reset
No
0 – No
1 – Yes
P11
Service Reminder (Cycles x 100)
240
P12
Input Status
-
P20
Open Input Function
0 (Timed Open)
P21
Input Switch Response
0 (Momentary)
P22 (RS-500 WIC Door Only)
Auxiliary Safety Response
1 (Enabled)
P23
Encoder Operation
0 (2 Channels)
P24
CMS Output Function
0
P25
CMS On-Time
15 (If P24=0)
P26
CMS Off-Time
10 (If P24=0)
PS1
Setup Door Limits
-
PS2
Set Open Limit
-
PS3
Set Close Limit
-
Section 6: Setting Limits
PS1 – Change Program Limits:
This can be set to Yes or No. To change the Open Limit (PS2) or Closed Limit (PS3), set PS1 to Yes,
then press the Mode button. To exit programming mode, set PS1 to No and press the Mode button.
PS2 – Set Open Limit:
When the Mode button is pressed after PS1 has been set, the door will open to the Home switch
position, then proceed toward the Open limit. Use the Up and Down arrows to set the door to a new Open limit, then press the
Mode button to proceed to the next parameter.
PS3 – Set Close Limit:
When the Mode button is pressed after the Open limit has been set, the door will close to the current
setting of the Closed limit. Use the Up and Down arrows to set the new Closed limit, then press the Mode button to exit
programming mode and resume displaying the Actual Position.