Part No 4801-5314 Rev 06-2015
Float & Pump Replacement
PolarCool
RollSeal, Inc. • 1733 County Road 68 • Bremen, Alabama 35033 • 256-287-7000
6A. For the old style pump see Figure 4. Loosen screws and nuts holding the old style
bracket. Remove old pump and bracket.
6B. For the new style pump see Figure 5. Cut the ribbon tie and remove pump.
7.
Attach new bracket, if required, with rivets provided as shown in Figure 4.
8.
Set pump on floor of PolarCool in front of bracket. NOTE: Make sure intake side of
pump is at bottom.
9.
Insert a ribbon tie, provided, through two holes of bracket.
10.
Wrap ribbon tie around pump as shown in Figure 5. Securely tighten ribbon tie to
anchor pump into position.
11. Attach water hose to hose fitting on pump. See Figure 6.
12.
Make sure all electrical power is disconnected from PolarCool. Stretch out pump
power cord. Insert pump power through conduit of electrical box to inside of
electrical box.
13.
Connect pump power cord to terminals of electrical box as shown in wiring Diagrams. See Figures 7 or 8.
14.
Close electrical box and securely tighten lid of electrical box.
15.
Bundle pump power cord with other cords using ribbon ties.
16.
Reconnect power and water.
17.
Test new pump for proper operation.
18.
Replace cool pads.
19.
Installation complete.
Figure 4
Bracket
Old style bracket
uses nuts and
Attach new style
bracket with rivets
provided
Figure 5
Replacement
Pump
Ribbon
Tie
Intake
Pump for PolarCool
(Appearance may
differ from picture)
Hose Fitting
Figure 6
Black
White*
Ground
To
Motor
2 Green
3 Red
4 Or
ange
6 Black
5 Or
an
g
e
1 Blue
Pump
To
Switches
Gr
ound
Black
White
Black
White
Ground
Single
Speed
Harness
TO MOTOR
Fan
Switch
White
*
Black*
B
lack
White
Ground
Pump
Switch
C d
Ground
Figure 7
Variable Speed Wiring Diagram
Figure 8
Single Speed Wiring Diagram