RollSeal PolarCool Series Скачать руководство пользователя страница 2

 

Part No 4801-5314 Rev 06-2015 

Float & Pump Replacement 

 PolarCool 

 

RollSeal, Inc.  •  1733 County Road 68  •  Bremen, Alabama 35033  •  256-287-7000 

 

 

 

Floats Mounted Inside the Cabinet 

NOTE: Water source must be turned off and/or disconnected to remove and 

replace float.

 

1.

 

Remove the old float assembly from the cabinet wall. 

Ensure electrical power has been disconnected and 

water supply is turned off and/or disconnected. 

See Illustration 4. 

2.

 

Remove the Pads. 

3.

 

Assemble the float valve lock nut and hose fitting to the bracket as shown in Illustration 5. 

 
 
 
 
 
 
 
 
 
 
 
 
 

 

4.

 

Attach the hose to the float assembly as seen in Illustration 6. 

5.

 

Attach the float assembly to the cabinet wall as shown in Illustration 7 with 1/4”x20x1/2” bolts and 
nuts. 

 
 
 
 
 
 

 

 

 

 

 

6.

 

Restore the water source and fill the reservoir. Ensure that the water 
fills to the correct level. 

NOTE: Water level in reservoir is normally 2-1/4" 

 1".  

See Float Adjustment if water level is not correct.  

 Warning! 

Disconnect All Power Sources Before Installing This Equipment! Failure To  

Disconnect Power Source Can Result In Property Damage, Serious Injury Or Death! 

!

 

Bracket 

Hose 

Fitting 

Float Arm 

Lock Nut 

Illustration 4 

Illustration 5 

Bolts 

New 
Float 

Illustration 6 

Illustration 7 