Product Overview

EVACOCM-01-V02-R3 Installation and Operation Manual

AutoCharge:EV OpenCharge

December 2021

Page 

4

of 

21

Product Overview

The AutoCharge:EV OpenCharge is an OCPP compliant, smart charging unit which has 

been designed to provide the Host with full visibility and control of its use and, for the 

driver, a simple to use EV charging solution activated via an RFID card/fob or an online 

web or phone application which allows control of the unit and views of their charging 

activity.

The AutoCharge:EV OpenCharge pedestal is available with the following power options:

Model Number Specification

OCPP0010

AutoCharge EV OpenCharge OCPP - 1x 3.6kW (16A) Type 2 socket

OCPP0011

AutoCharge EV OpenCharge OCPP - 1x 7.2kW (32A) Type 2 socket

OCPP0020

AutoCharge EV OpenCharge OCPP - 2x 3.6kW (16A) Type 2 sockets

OCPP0021

AutoCharge EV OpenCharge OCPP - 2x 7.2kW (32A) Type 2 sockets

OCPP0012

AutoCharge EV OpenCharge OCPP Superfast - 1x 11kW (16A) Type 2 socket

OCPP0013

AutoCharge EV OpenCharge OCPP Superfast - 1x 22kW (32A) Type 2 socket

OCPP0022

AutoCharge EV OpenCharge OCPP Superfast - 2x 11kW (16A) Type 2 sockets

OCPP0023

AutoCharge EV OpenCharge OCPP Superfast - 2x 22kW (32A) Type 2 sockets

NOTE: 

GPRS/mobile communication at the installation site requires a signal strength of 14 

CSQ or better.

Refer to the Product Specification on page 5 for further details.

Features

x

Mode 3 (IEC 61851-1) charging

x

Type 2 (IEC 62196) charging socket(s) 

c/w security hatchlock(s)

x

Built-in RFID reader

x

Built-in AC overload protection (MCB)

x

Built-in AC & DC fault protection (RCD)

x

Built-in LED charging status indicator 

socket halo(s)

x

Built-in class 1 MID compliant kWh 

meter(s)

x

IP Rated, UV stabilised, corrosion 

resistant & fire retardant

x

OCPP 1.6 compliant (Can integrate 

with any back office)

x

OLEV Grant Fundable under the 

Workplace Charging Scheme

x

EV driver Pay-to-Charge smartphone 

integration 

x

Smart charging control via mobile 

phone and/or RFID

x

On board GPRS modem with antenna

x

Ethernet connection

x

Remote firmware updates

Safety

AutoCharge:EV OpenCharge

EVACOCM-01-V02-R3 Installation and Operation Manual

Page 

3

of 

21

December 2021

Safety

This manual is specifically applicable to the AutoCharge:EV OpenCharge electric vehicle 

charging product and is provided as a guide to its installation and operation.

IMPORTANT: 

Installers and End Users

must

read and 

understand

the content 

of this manual before installation and/or use of the product.

Installation must

only

be performed by someone who is properly qualified and 

competent to do so in accordance with the current legislation in force in the 

geographical location of the installation.

x

Rolec Services Ltd cannot accept any responsibility for improper installation or any 

problems arising from improper installation.

NOTE: 

Damage to the equipment, connected systems or to property caused by 

improper installation are the responsibility of the installer.

x

The information provided in this manual must ONLY be used with the model(s) listed on 

page 1 of this manual.

x

The information provided in this manual must NOT be used with any other product.

x

The content of this manual may be updated by the manufacturer as required.

x

Do NOT use the equipment for anything other than its intended purpose.

x

Do NOT modify the equipment unless specifically instructed to do so by the 

manufacturer.

x

Do NOT attempt to repair the equipment unless specifically instructed to do so by the 

manufacturer.

x

To maintain electrical safety, the body enclosure of the product (access covers) must 

be secured in their correct location using the supplied fasteners and the seal must be 

sufficient to maintain the IP rating of the enclosure.

x

Fasteners used to mount the product in its working location must be sufficient for the 

task and the specific mounting point.

x

If required, fasteners used to mount the product in its working location should be 

sealed to maintain the IP rating of the enclosure.

x

Damage to the product may render it unsafe. The product must be electrically 

isolated and NOT used until appropriate remedial action has been performed.

Safety Advice within this Manual

Rolec manuals use a system of warnings, cautions and notes.

x

WARNINGS

concern the safety of installers/end user and will be given before the 

detail/instructions in the manual.

x

CAUTIONS 

concern the potential for damage to the equipment and will be given 

before the detail/instructions in the manual.

x

NOTES 

are given to provide additional information and/or to highlight information of 

importance. They will be given either before or after the detail/instructions as 

appropriate and may use different wording (such as IMPORTANT) where emphasis is 

required.

Warnings, Cautions and Notes may be repeated several times as appropriate and may 

be preceded by a hazard symbol where appropriate.

Содержание OCPP0010

Страница 1: ...AUTOCHARGE EV EV OPENCHARGE GPRS Ethernet Communication INSTALLATION OPERATION MANUAL MODELS SINGLE PHASE OCPP0010 1 X 3 6kW OCPP0011 1 X 7 2kW OCPP0020 2 X 3 6kW OCPP0021 2 X 7 2kW 3 PHASE OCPP0012 1...

Страница 2: ...hase OCPP0010 OCPP0011 OCPP0020 OCPP0021 Three Phase Superfast OCPP0012 OCPP0013 OCPP0022 OCPP0023 Document Type Installation and Operation Manual Document Code EVACOCM 01 V02 R3 Language UK English O...

Страница 3: ...nstallation 9 Base Installation If Supplied 9 If a Base is Not Supplied 10 Schematics 10 Install the Charger 14 Commissioning 15 Commissioning with VendElectric 15 After Installation 15 Operation 16 V...

Страница 4: ...do so by the manufacturer x Do NOT attempt to repair the equipment unless specifically instructed to do so by the manufacturer x To maintain electrical safety the body enclosure of the product access...

Страница 5: ...ge OCPP Superfast 1x 11kW 16A Type 2 socket OCPP0013 AutoCharge EV OpenCharge OCPP Superfast 1x 22kW 32A Type 2 socket OCPP0022 AutoCharge EV OpenCharge OCPP Superfast 2x 11kW 16A Type 2 sockets OCPP0...

Страница 6: ...mensions 1275 x 323 x 270 mm HxWxD Material Steel Enclosure Mass 24 5kg Operating Temperature 30 C to 50 C Operating Humidity Range 5 to 95 Figure 1 General Arrangement and Dimensions 2 socket model s...

Страница 7: ...0Hz Single Phase Cable Terminals 3x 50mm Single Phase Communications GPRS Requires a signal strength of 14 CSQ or better or Requires an RJ45 ethernet cable Operating Temperature 30 C 50 C Product Code...

Страница 8: ...n x Enclosure IP54 Socket IP54 BS EN 60529 1992 A2 2013 x Enclosure IK10 BS EN 62262 Plug s Socket s x BS EN 62196 1 2014 BS EN 62196 2 2017 Fire Rating x UL94 Flame Rating at V2 for 1 5mm and 3 0mm R...

Страница 9: ...nt enclosure Labels may be in the form of adhesive stickers plates and or moulded into the surface of components Information Labels Figure 2 Typical Product Rating Label Figure 3 Typical Fascia Label...

Страница 10: ...arger and any accessories have not been damaged in transit NOTE Items damaged in transit must first be reported to the courier and then to the supplier Where possible photographic evidence of package...

Страница 11: ...Single Socket AutoCharge EV OpenCharge Schematic ACEN0095 C20 1 2 O OFF ACEQ0040 C6 2 N N 1 N N T A2 A1 14 11 12 WHITE J602 X1 X603 X601 X602 X600 1 7 6 2 4 5 1 3 4 6 WHITE 1 2 3 14 11 25 E CP PP N L3...

Страница 12: ...NG CONTROLLER RHS VIEW GREENFLUX SMART CHARGING CONTROLLER LHS VIEW 2 1 10 8 13 8V Max 2A Max 24Watt OUTPUT 12V 2A E CP PP N L3 L2 L1 V N INPUT 100 240VAC 0 88A 50 60Hz A1 L V 11 A2 12 14 3 2 1 SOCKET...

Страница 13: ...50Hz 1 3 5 7 24 23 21 20 2 4 6 8 ACEQ0040 C6 2 N N 1 N N T ACEO0240 63A 30mA 400 415V 50 60 Hz N 1 3 5 N 2 4 6 LIVE 1 LIVE 2 LIVE 3 NEUTRAL EARTH A1 A2 WHITE J602 X1 X603 X601 X602 X600 1 7 6 2 4 5 1...

Страница 14: ...12V 2A E CP PP N L3 L2 L1 V N INPUT 100 240VAC 0 88A 50 60Hz A1 L V 11 A2 12 14 3 2 1 SNUBBER SOCKET 1 SOCKET 2 A B 1000imp kWh DTS353F 2 EN50470 1 3 kWh 25 C to 55 C 3X230 400V 0 25 5 80 A 50Hz 1 3 5...

Страница 15: ...tallation IMPORTANT NOTE It is the responsibility of the installing engineer to satisfy themselves that all cable terminations throughout this product are secure and tight and have not become loose st...

Страница 16: ...reliminary tasks listed in the Host s Guide shown at the end of this manual must have been performed by the customer Host before commissioning can proceed 2 To complete commissioning refer to the Inst...

Страница 17: ...r to the EV Driver App User Guide included within the charger packaging Status Indicator Guide Flashing blue light Socket Available Flashing green light Socket Available for Plug and Go charging optio...

Страница 18: ...ions 3 Charging cables should be routed between the charger and the vehicle so as not to cause an obstruction or trip hazard 4 Charging cables must NOT be left connected to the charger when not in use...

Страница 19: ...eer in accordance with applicable regulations for the region of use A typical maintenance inspection and testing schedule is provided on the next page This schedule alternates on a quarterly basis bet...

Страница 20: ...sical damage x All warning labels present and legible x Status Indicators operating and displaying correct status x If installed check the condition of the charging socket contacts and socket flap x I...

Страница 21: ...vises the Client how this can be done during the handover process We also recommend that you consider entering a service and support agreement with your preferred Installer to ensure you are covered f...

Страница 22: ...3 CONTACT US 4 COMPLETE For more information call 01205 725765 Email support vendelectric com Or visit vendelectric com As a part of its services VendElectric will routinely monitor the connectivity a...

Страница 23: ......

Страница 24: ...THE UK S LEADING MANUFACTURER OF EV CHARGING POINTS t 01205 724773 e enquiries rolecserv co uk www rolecserv com...

Отзывы: