Part 2
27
Stopping the Cutting Process Immediately
In the case that you begin cutting and then find that you have sent the wrong cutting data, perform the following
operation.
2
Download Data
Stop the transfer of data to the PNC-3100
by operating software of computer.
• For details of the data transfer stop
method, refer to the manual of the com-
puter or software you use.
Device Name
PNC-3100
Interface
RS-232C
Protocol
Baud rate
: 9600
Data bit
: 8
Stop bit
: 1
Parity
: None
Handshake
: Xon/Xoff
OK
3
Press the
[BUFFER CLEAR]
key for at
least 0.5 seconds.
• The data buffer is cleared.
• When data in the buffer is erased, the
coordinate display for the Y axis begins
to flashes.
1
Press the
[PAUSE ON]
key.
• PAUSE LED comes ON.
• The unit stops after completing the cut-
ting operation in progress.
4
Press the
[OFF]
key.
• PAUSE LED goes OFF.
• Download the current of data to the PNC-
3100 by operating software of computer.
• If necessary set the home position (refer
to page 14) and Z0 (refer to page 15).
Download data now. Click "