Part 1
5
Switch
panel
X
-AXIS
XYZ Coordinate
Display
REPLOT Key
This keys carries out replotting (recutting) when cutting data is
present in the PNC-3100 data buffer.
ENTER Key
In combination with the
[Z0]
,
[Z1]
,
[Z2]
and
[HOME]
keys, the
key designates the positions of Z0, Z1, Z2 and HOME. Also, if this
key is pressed when PAUSE is ON, the moving speeds in each axis
direction are shown on the XYZ coordinate display.
Z Axis Position
Keys
These keys are used to set the positions of Z0, Z1 and Z2 in
combination with the
[ENTER]
key. Also, the tool is moved to the
ZO, Z1 or Z2 position when the appropriate key is pressed. In the
interests of safety, movement to Z1 does not begin until the
[Z1]
key
is pressed for 0.5 seconds.
HOME Key
This key is used to set the HOME position (refer to page 14) in
combination with the
[ENTER]
key. Also, if you continue pressing
this key for approx. 0.5 seconds, the tool is moved to the HOME
position.
SENSOR Key
In the case that Z0 setting is performed using the optional sensor, this
key functions as the sensor ON/OFF switch.
VIEW Key
If this key is pressed for 0.5 seconds or more, the spindle raised and
the XY table moves toward the front of the unit and stopped.
This display shows the coordinate values of each axis in 1/100 mm
units. For the X and Y axes, the home position coordinates (refer to
page 14) are (0, 0). For the Z axis, Z0 (refer to page 15) is displayed
as "0."
X
Y
Z
Z
-AXIS
Y
-AXIS
X
-AXIS
SENSOR
BUFFER
JOG
SPINDLE TEST
ON / OFF
JOG
HOME
Z2
Z0
Z1
ENTER
REPLOT
ON / OFF
CLEAR
PAUSE
ON
OFF
VIEW
Z
* This figure is X
Coordinate Display.
Содержание PNC-3100 CAMM-3
Страница 54: ...Appendix 44 MEMO ...
Страница 55: ...Printed in JAPAN R9 980216 PNC 3100 ...