Architects & Engineers Specifi cation

The digital mixer shall be designed as an 

integrated system including Ethernet audio 

transmission, digital audio processing, integrated 

digital recording using an optional USB memory 

key, and digital mixing. The system shall have 

the ability to be expanded to a maximum of 90 

physical inputs and 90 physical outputs using up 

to 2 input and output modules. The system shall 

have two Ethernet transmission ports that can 

each be connected to an input module comprising 

an 8-input stage box, a 16-input stage box or a 

modular 40-channel input box. The inputs shall 

be of very high quality and accept both line 

and microphone level inputs with individually 

selectable phantom power. The input gains or 

trims shall be controllable in 1 dB increments and 

these settings, as well as their phantom power 

settings, shall be remotely controllable from the 

mixing control surface. The gain and phantom 

power parameters shall be stored with the 

channel settings for recall later. 

The mixing system shall include a mixing control 

surface that includes 25 touch-sensitive moving 

faders. It shall also include 25 Mute buttons, 25 

Solo buttons and 25 Select buttons. Pressing 

the Select button shall return the display to the 

selected channel or bus’s Edit screen. There 

shall be 3 buttons that assign 24 of the faders 

to control channels 1-24, channels 25-48, or 

the buses. A fourth button shall assign the 

faders to control the individual User Fader 

settings for the selected User. It shall also have 

a dedicated Touch Sense button for turning the 

touch sensitive fader function on and off. It shall 

also have a dedicated Sends on Fader button 

allowing fader control of each channel’s send 

level to the selected bus. It shall also have 10 

knobs dedicated to adjusting the channel and 

bus EQ parameters. It shall also have 16 buttons 

dedicated to choosing any of the 16 Aux buses. 

It shall also have two dedicated Threshold knobs 

for adjusting the threshold parameter for the 

Gates, Compressors and Limiters. It shall also 

have a Help button. This button shall be used to 

access built-in educational and instructional data 

for the system’s main features. This button shall 

be context sensitive, allowing direct access to 

instructional text for most parameters using that 

parameter’s button.

The mixing control surface shall have 3 Ethernet 

ports. Two of the Ethernet ports, A and B, can be 

connected, using Cat5e or Cat6 cables, to stage 

units supporting 16 inputs and 8 outputs, 8 inputs 

and 16 outputs, or up to 40 inputs each. Using 

a gigabit switch, both of the cables can be split 

to support up to 40 output audio paths. The A 

port shall support 8 user output choices from any 

channel, bus or matrix plus up to 32 stage inputs. 

The third Ethernet port on the control surface 

shall also provide 8 user output choices from any 

channel, bus or matrix; plus up to 32 stage inputs. 

The B port shall support up to 40 output choices 

from any channel, bus or matrix.

The mixing control surface shall be able to mix 

up to 48 channels of audio to 16 Aux buses or 

a stereo Main bus. The audio path from each 

channel shall be selectable from the pre EQ, 

pre fader and post fader positions. It shall also 

provide 8 Matrices that accept inputs from all 

buses and up to 2 unique channels each. The 

sends to the Matrices shall be selectable from pre 

EQ, prefader and post fader positions. 

The mixing control surface shall have 8 XLR 

mic/line inputs, 8 XLR line level outputs and 

stereo inputs and stereo digital outputs. The 

control surface shall provide up to 8 external 

insert paths, available from any channel, bus 

or matrix; using the surface’s XLR inputs and 

outputs. The mixing control surface shall provide 

5 bands of adjustable equalization on each of 

the 48 channels along with 24 assignable gates 

and 24 assignable compressors. It shall also 

provide 4 bands of equalization and a limiter on 

each of the 16 Aux buses and the Main LR bus. 

The mixing control surface shall include libraries 

for storing various channel, bus and system 

parameters. These libraries shall include a 

Channel library, Patchbay library, EQ library, and 

Gate and Compressor libraries. Each of these 

shall have at least 100 user storage patches. 

The mixing control surface shall provide 4 stereo 

digital effects processors each of which can also 

be confi gured as a dual mono processor. These 

processors shall be assignable to any channel, 

bus or matrix as an insert or as loop effects using 

an Aux bus. In addition it shall provide four 31-

band graphic equalizers assignable to any of the 

buses or matrices. 

The mixing control surface shall include 300 

scenes that store all of the channel, bus and 

processing parameters. It shall also provide 

16 user buttons that can be assigned to 

direct scene recall, the tempo parameter for a 

processor confi gured as a digital delay, and other 

parameters. The mixing control surface shall also 

include an XLR input with phantom power to be 

used for a talkback microphone. The talkback 

microphone input shall be assignable to any or 

all Buses or Matrices. There shall also be an 

onboard tunable Oscillator and Noise Generator 

assignable to any Buses or Matrices. It shall also 

have a large, color, dimmable backlit 480x800 

TFT screen. It shall also provide a connector 

designed for an optional console light. 

The mixing control surface shall also have a 

USB slot that will support a USB storage key. 

The system shall support direct 16-bit, .linear 

wav fi le recording or playback via this USB key 

connected to this port. The USB key shall also 

be used as storage for console parameters 

including all libraries and scenes. The mixing 

control surface shall also support the creation 

of an Administrator password and an unlimited 

number of individual user profi les which shall be 

stored to, and require the use of, a USB key for 

access. The Administrator shall be able to restrict 

any user from accessing certain or all faders, 

and a range of mixing system parameters. Each 

user shall also have their own assignment for the 

16 User buttons and the 24 User faders. These 

faders shall be accessible from a User Fader 

bank button. 

The mixing control surface shall provide 8 mute 

groups and 8 DCA groups. The DCA groups shall 

provide level control from one DCA master fader 

of a user-assignable collection of channels and 

buses. The mixing control system shall provide a 

balanced headphone output. This output shall be 

assigned to the Monitor bus, which shall also be 

available as an output to any physical outputs in 

the system. The headphone output shall have an 

individually adjustable output level control. The 

mixing control surface shall also provide meter 

screens showing channel and bus levels. The 

channel levels shall be selectable with choices 

including post preamp, pre fader and post fader. 

Each fader shall also have a companion LED 

meter ladder that displays that channel’s levels.

The mixing control surface shall have a USB port 

that, when connected to a PC computer loaded 

with control software, can be used to control the 

channel, bus, effects and other parameters of the 

whole mixing system.

The system shall be a Roland V-Mixing System 

including an M-400 mixing control surface and the 

appropriate input and output modules.

M-400 Digital V-Mixing System