Roland HP 337 Скачать руководство пользователя страница 5

5

GM2 System On

Status

Data byte

Status

F0H

7EH 7FH 09H 03H

F7H

Byte

Explanation

F0H

Exclusive status

7EH

ID number (Universal Non-realtime Message)

7FH

Device ID (Broadcast)

09H

Sub ID#1 (General MIDI Message)

03H

Sub ID#2 (General MIDI 2 On)

F7H

EOX (End Of Exclusive)

*

When this message is received, the HP-337 will be able to receive the messages specified
by General MIDI 2, and use the General MIDI 2 soundmap.

*

There must be an interval of at least 50 ms between this message and the next.

GM System Off

"GM System Off" is a command message that resets the internal state of the HP-337 from the
GM state to its native condition. The HP-337 will reset to the GS default state.

Status

Data byte

Status

F0H

7EH, 7FH, 09H, 02H

F7H

Byte

Explanation

F0H

Exclusive status

7EH

ID number (Universal Non-realtime Message)

7FH

Device ID (Broadcast)

09H

Sub-ID#1 (General MIDI message)

02H

Sub-ID#2 (General MIDI Off)

40H

EOX (End of exclusive)

*

When this message is received, the HP-337 will reset to the GS default state.

*

There must be an interval of at least 50 ms between this message and the next.

GS reset

GS Reset is a command message that resets the internal settings of a device to the GS initial
state. This message will appear at the beginning of GS music data, and a GS device that
receives this message will automatically be set to the proper state to correctly playback GS
music data. 

Status

Data byte

Status

F0H

41H, 10H, 42H, 12H, 40H, 00H, 7FH, 00H, 41H

F7H

Byte

Explanation

F0H

Exclusive status

41H

ID number (Roland)

10H

Device ID (dev: 00H-1FH (1-32), Initial value is 10H (17))

42H

Model ID (GS)

12H

Command ID (DT1)

40H

Address MSB

00H

Address

7FH

Address LSB

00H

Data (GS reset)

41H

Checksum

F7H

EOX (End Of Exclusive)

*

When this message is received, Rx.NRPN will be ON.

*

There must be an interval of at least 50 ms between this message and the next.

Universal Realtime System Exclusive Messages

Master volume

Status

Data byte

Status

F0H

7FH, 7FH, 04H, 01H, llH, mmH

F7H

Byte

Explanation

F0H

Exclusive status

7FH

ID number (universal realtime message)

7FH

Device ID (Broadcast)

04H

Sub ID#1 (Device Control messages)

01H

Sub ID#2 (Master Volume)

llH

Master volume lower byte

mmH

Master volume upper byte

F7H

EOX (End Of Exclusive)

*

The lower byte (llH) of Master Volume will be handled as 00H.

Master Fine Tuning

Status

Data byte

Status

F0H

7FH, 7FH, 04H, 03H, llH, mmH 

F7H

Byte

Explanation

F0H

Exclusive status

7FH

ID number (universal realtime message)

7FH

Device ID (Broadcast)

04H

Sub ID#1 (Device Control)

03H

Sub ID#2 (Master Fine Tuning)

llH

Master Fine Tuning LSB

mmH

Master Fine Tuning MSB

F7H

EOX (End Of Exclusive)

mm, ll : 00 00H - 40 00H - 7F 7FH(-100 - 0 - +99.9 [cents])

Master Coarse Tuning

Status

Data byte

Status

F0H

7FH,7FH,04H,04H,llH,mmH 

F7H

Byte

Explanation

F0H

Exclusive status

7FH

ID number (universal realtime message)

7FH

Device ID (Broadcast)

04H

Sub ID#1 (Device Control)

04H

Sub ID#2 (Master Coarse Tuning)

llH

Master Coarse Tuning LSB

mmH

Master Coarse Tuning MSB

F7H

EOX (End Of Exclusive)

llH :

ignored (processed as 00H)

mmH : 

28H - 40H - 58H (-24 - 0 - +24 [semitones])

Global Parameter Control

Parameters of the Global Parameter Control are newly provided for the General MIDI 2.

Reverb Parameters

Status

Data byte

Status

F0H

7FH,7FH,04H,05H,01H,01H,01H,01H,01H,ppH,vvH

F7H

Byte

Explanation

F0H

Exclusive status

7FH

ID number (universal realtime message)

7FH

Device ID (Broadcast)

04H

Sub ID#1 (Device Control)

05H

Sub ID#2 (Global Parameter Control)

01H

Slot path length

01H

Parameter ID width

01H

Value width

01H

Slot path MSB

01H

Slot path LSB (Effect 0101: Reverb)

ppH

Parameter to be controlled.

vvH

Value for the parameter.

F7H

EOX (End Of Exclusive)

pp=0

Reverb Type
vv = 00H

Small Room

vv = 01H

Medium Room

vv = 02H

Large Room

vv = 03H

Medium Hall

vv = 04H

Large Hall

vv = 08H

Plate

pp=1

Reverb Time
vv = 00H - 7FH

0 - 127

Содержание HP 337

Страница 1: ...t received when Rx MODULATION OFF Initial value is ON The resulting effect is determined by System Exclusive messages With the initial settings this is Pitch Modulation Depth Portamento Time Controlle...

Страница 2: ...te BnH 4DH vvH n MIDI channel number 0H FH ch 1 ch 16 vv Vibrato Depth Value relative change 00H 7FH 64 0 63 Initial Value 40H no change Some Tones will not exhibit any change Vibrato Delay Controller...

Страница 3: ...changes or in the range of change Parameters marked absolute change will be set to the absolute value of the parameter regardless of the preset value Data entry LSB llH is ignored RPN MSB LSB Control...

Страница 4: ...BnH 7FH 00H n MIDI channel number 0H FH ch 1 ch 16 The same processing will be carried out as when All Sounds Off and All Notes Off is received and the corresponding channel will be set to Mode 3 Syst...

Страница 5: ...at least 50 ms between this message and the next Universal Realtime System Exclusive Messages Master volume Status Data byte Status F0H 7FH 7FH 04H 01H llH mmH F7H Byte Explanation F0H Exclusive statu...

Страница 6: ...e message 7FH Device ID Broadcast 09H Sub ID 1 Controller Destination Setting 03H Sub ID 2 Control Change 0nH MIDI Channel 00 0F ccH Controller number 01 1F 40 5F ppH Controlled parameter rrH Controll...

Страница 7: ...ets of 128 bytes or less If Data Set 1 is transmitted successively there must be an interval of at least 40 ms between packets Regarding the checksum please refer to section 4 p 13 2 Transmit data Arr...

Страница 8: ...F0H 7EH 10H 06H 02H 41H 42H 00H 00H 09H 00H 01H 00H 00H F7H Byte Explanation F0H Exclusive status 7EH ID number universal non realtime message 10H Device ID use the same as the device ID of Roland 06H...

Страница 9: ...03 Refer to section 4 Supplementary material About tuning p 14 40 00 04 00 00 01 00 7F MASTER VOLUME 0 127 7F 127 F0 7F 7F 04 01 00 vv F7 40 00 05 00 00 01 28 58 MASTER KEY SHIFT 24 24 semitones 40 0...

Страница 10: ...01 Rx RPN OFF ON 01 ON 40 1x 0A 00 00 01 00 01 Rx NRPN OFF ON 00 01 OFF ON When GM1 System On and GM2 System On are received Rx NRPN will be set OFF When GS Reset is received it will be set ON 40 1x...

Страница 11: ...40 1x 46 00 7F SCALE TUNING F 64 63 cent 40 0 cent 40 1x 47 00 7F SCALE TUNING G 64 63 cent 40 0 cent 40 1x 48 00 7F SCALE TUNING G 64 63 cent 40 0 cent 40 1x 49 00 7F SCALE TUNING A 64 63 cent 40 0 c...

Страница 12: ...CC1 LFO1 TVF DEPTH 0 2400 cent 00 0 cent 40 2x 46 00 00 01 00 7F CC1 LFO1 TVA DEPTH 0 100 0 00 0 40 2x 47 00 00 01 00 7F CC1 LFO2 RATE CONTROL 10 0 10 0 Hz 40 0 Hz 40 2x 48 00 00 01 00 7F CC1 LFO2 PI...

Страница 13: ...atus and n is the MIDI channel number Since EH 14 and 49H 73 this is a Program Change message with MIDI CH 15 program number 74 Flute in GS Example 3 EA 00 28 EnH is the Pitch Bend Change status and n...

Страница 14: ...7 39 440 0 0 00 40 00 0 00 04 00 00 0 439 0 3 94 3D 3D 323 00 03 0D 09 39 438 0 7 89 3A 7A 646 00 03 0B 01 79 Example Set the tuning of MIDI channel 3 to A4 442 0 Hz Send RPN 1 to MIDI channel 3 From...

Страница 15: ...1 4 8 8 38 00h 48h 09h Glocken 1 00h 00h 0Ah GS Music Box 1 8 39 00h 40h 0Ah Music Box 1 4 5 00h 48h 0Ah Music Box 1 00h 00h 0Bh GS Vibe 1 8 40 00h 40h 0Bh Vibraphone 1 4 1 00h 48h 0Bh Vibraphone 1 0...

Страница 16: ...h 40h 21h Fingered Bs 1 00h 48h 21h Fingered Bs 1 00h 00h 22h GS Picked Bs 1 8 86 00h 40h 22h Picked Bs 1 00h 41h 22h Mute PickBs 1 00h 48h 22h Picked Bs 1 00h 00h 23h Fretless Bs 1 8 87 00h 48h 23h F...

Страница 17: ...00h 00h 48h Piccolo 1 8 139 00h 48h 48h Piccolo 1 00h 00h 49h GS Flute 1 8 140 00h 40h 49h Flute 1 8 1 00h 48h 49h Flute 1 00h 00h 4Ah Recorder 1 8 141 00h 48h 4Ah Recorder 1 00h 00h 4Bh Pan Flute 1 8...

Страница 18: ...00h 00h 6Ch Kalimba 1 4 11 8 184 00h 48h 6Ch Kalimba 1 00h 00h 6Dh Bagpipe 1 8 185 00h 48h 6Dh Bagpipe 1 00h 00h 6Eh Fiddle 1 8 186 00h 48h 6Eh Fiddle 1 00h 00h 6Fh Shanai 1 8 187 00h 48h 6Fh Shanai 1...

Страница 19: ...249 02h 00h 7Fh Lasergun 1 8 250 03h 00h 7Fh Explosion 2 8 251 KR 337 Drum MAPPING CC0 CC32 PC Tone Name Notes 00h 40h 00h STANDARD 8 6 00h 40h 08h ROOM 8 242 00h 00h 10h POWER 8 243 00h 00h 18h ELECT...

Отзывы: