34
Instruc- Compati-
Format
Parameter
Range ([ ]: Default)
Expanation
tion
bility
SA
SA;
None
SC
SC Xmin,Xmax,Ymin
Xmin,Ymin: User
: *1
,Ymax(,type(,left,bottom));
coordinate of P1
SC Xmin,Xfactor,Ymin
Xmax,Ymax: User
: *1
,Yfactor,type;
coordinate of P1
SC;
type: Scaling type
: 0,1,2
left
: 0—100 (%)
bottom
: 0—100 (%)
Xfactor: User X
: *1
coordinate of P1
Yfactor: User Y
: *1
coordinate of P2
SG
SG g;
g: Group number
: 0—8 [0]
SG;
SI
SI w.h;
w: Character width
: *1 (cm) [0.285cm]
SI;
h: Character height
: *1 (cm) [0.375cm]
SL
SL tanø;
tanø: Character slant
: *1 [0]
SL;
SM
SM s;
s: Character or symbol
: CHR$ (33)—CHR$ (58)
SM;
,CHR$ (60)—CHR$ (126)
(If no parameter, symbol mode OFF)
SP
SP n;
n: Pen number
: 0—8 [0]
SP;
SR
SR w,h;
w: Character width
: *1 (%) [0.285cm]
SR;
h: Character height
: *1 (%) [0.375cm]
SS
SS;
none
TL
TL lp(,lm);
lp: Tick length in
: *1 (%) [0.5%]
TL;
positive direction
lm: Tick length in
: *1 (%) [0.5%]
negative direction
UC
UC (c,)É¢x1,É¢y1((,c),
c: Pen cotrol value
: -8388608—-9999,+9999—+8388607
• The number of allotted units of each font is as follows:
É¢x2,É¢y2...,É¢xn,É¢yn);
xn: Number of
Fixed character width font: 48(W) x 64(H)
UC;
X-axis directional
: -9998—+9998
Optimum character width font: 42(W) x 72(H)
moving units
• Normal characters are plotted within the following range. It
yn: Number of
: -9998—+9998
means that if you define a character so as to be accommodated in
Y-axis directional
there, it becomes the same size as a normal character.
moving units
Fixed character width font: 32(W) x 32(H)
Optimum character width font: 28(W) x 36(H)
UF
UF d1(,d2,.....d20);
d1—d20:
: *2
The maximum number of parameter you can set is 20.
UF;
Hatching spacing
partition ratio
VS
VS v(,n);
v: Pen speed
: 1-42 cm/sec
• The pen speed can be set in the unit of 1cm/sec.
VS;
n: Pen number
[Value by automatic pen sensing]
• The parameter range of 1—8388607 is for no error.
: 1-8 [All eight pens]
• If the pen speed is set over 42, it will be set at 42.
• If the pen number is set over 9, the instruction is ignored.
WD
WD c1c2.....cn
cn: Character
[label terminator]
WD [label terminator]
WG
WG r,ø1,øc(,ød);
r: Radius
: *1
• You can input a polygon of up to 250 vertices into the polygon
ø1: Start angle
: *3
buffer in the state of being initialized. If you, however, input a
øc: Center angle
: *3
polygon of vertices more than the buffer capacity, an error occurs.
ød: Chord tolerance
: *3 [5°]
XT
XT;
None
• The default tick length of X-axis is 0.5% of (P2y-P1y) in the
positive and negative directions, respectively.
YT
YT;
None
• The default tick length of Y-axis is 0.5% of (P2x-P1x) in the
positive and negative directions, respectively.