List of RD-GL II
Related Instructions
* 1: - ( 2
23
)—( 2
23
-1)
* 2: - 0— + ( 2
23
-1)
* 3: - ( 23 ) —+ ( 2
23
-1)
* 4: - ( 2
15
)— + ( 2
15
-1)
The list provides the instruction compatibility of the
DXY-1350A/1150A with the RD-GL II instruction
system and the parameters of these instruction.
: Compatible.
: Ignored.
: Incompatible.
Instruc- Compati-
Format
Parameter
Range ([ ]: Default)
Expanation
tion
bility
AA
AA x,y,øc(,ød);
x,y: Center
: *1
coordinate
øc: Center angle
: *3
ød: Chord tolerance
: *3 [5°]
AF
AF;
None
AH
AH;
None
AP
AP n;
n: Pen control value
0-225 (Decimal fractions are rounded.)
AP;
AR
AR x,y,øc(,ød);
x,y: Relative
: *1
coordinates to the center
øc: Center angle
: *3
ød: Chord tolerance
: *3 [5°]
BL
BL c1c2...cn
cn: Character
The maximum character buffer capacity, including control
[label terminator]
characters (e.g., label terminator) is 150 characters. Characters
BL [label terminator]
more than 150 are ignored.
CA
CA n;
n: Character set
: -1,0-59,70,80,99,101
•Any character number without the range of *1 results in error
CA;
number
(3). If a character number is within that range, it results in error
(5) and the instruction is ignored.
CC
CC øc;
øc: Center angle
: *3 [5°]
The maximum center angle is 45°. This means that even if
CC;
specifying a center angle more than 45°, 45° will be set.
CI
CI r(,ød)
r: Radius
: *1
ød: Chord tolerance
: *3 [5°]
CM
CM n1(,n2);
n1: Character set
0-3
mode
(Decimal fractions are rounded) [0]
n2: Fall back mode
: 0 or 1
(Decimal fractions are rounded) [0]
CP
CP nx,ny ;
nx: The number of X-
: *1 (Decimal fractions are rounded)
If any pen moving distance exceeds 8388607 and also any pen
CP ;
axis directional characters
movement to any coordinates exceeding *1, it results in error (3)
ny: The number of Y-
: *1 (Decimal fractions are rounded)
and the instructions are ignored.
axis directional characters
CS
CS n;
n: Character set
: -1,0—59,70,80,99,101
Any character number without the range of *1 results in error (3).
CS;
number
If a character number is within that range, it results in error (5)
and the instruction is ignored.
CT
CT n;
n: Chord tolerance
: 0 or 1
CT;
mode
(Decimal fractions are rounded) [0]
DC
DC;
None
DF
DF;
None
DI
DI run,rise;
run: X-axis
: *1 [1]
directional vector
DI;
rise: Y-axis
: *1 [0]
directional vector
DL
DL n(,pc),x1,y1.....
n: Character number
: 33—126 (Decimal fractions are rounded)
(,pc).....,xn,yn;
DL n;
pc: Pen control
: -128 (Decimal fractions are rounded)
DL;
xn,yn: Grid
: -127—+127 (Decimal fractions are rounded)
coordinate values
DP
DP;
none
DR
DR run,rise;
run: X-axis
: *1 [1]
DR;
directional vector
rise: Y-axis
: *1 [0]
directional vector
DS
DS s,n;
s: Slot number
: 0—1 (RD mode)
DS;
0—3 (ISO mode)
(Decimal fractions are rounded) [0]
n: Character set
: -1,0—60,70,80,99
number
(Decimal fractions are rounded)