1 R emove the backing of the cleaning pad.
2 Move the platen to the right side.
3 Place the new cleaning pad by pushing it toward the
left side.
** Make sure that the cleaning pad is not loose.
A ffix the new cleaning pad.
R emove the old cleaning pad from its right side.
Check the following:
1. Make sure that the there is a gap between the platen
and the cleaning pad.
2. Make sure that the platen damper moves in 4 direc-
tions: left, right, front and rear.
If the platen doesnÕt move smoothly, it could cause poor
printing results.
2
3
1
4 - E xchange the C leaning P ad
P laten
B acking
C leaning P ad
C leaning P ad
Make s ure to replace the cleaning pad when it becomes dirty (turns brown) or fluffy.
.
Us ing a dirty or fluffy cleaning pad could res ult in a damage to the head.
1
2
3
4