ROLA-CHEM Digital Controller                                        PN 554135      12/26/18                                               Page: 9 of 24 

Modes:  

The controller has four modes of operation: 

  ON/OFF mode. 

  AUTO mode – normal operation mode 

  pH - setting mode 

  ORP - setting mode 

To move from one mode to another simply press the MODE button.  
The illuminated lamp indicates the current mode. 
 

3.3.1 On/off mode:   

 

To turn the controller “ON”: press the MODE button.  

 

To turn the controller “OFF”: press and change MODE to pH or ORP and hold the MODE 

button for two seconds until both displays read “OFF”.  Release the MODE button and the 
controller turns off and the displays go blank.   
Note: Turning the controller “OFF” using the MODE button simply turns off the controller 
functions, but does not turn off the power to the controller. The ‘FLOW’ lamp located at the 
center of the controller is both the power light and a flow indicator when an optional flow 
switch is used. 
 

3.3.2 AUTO mode:

 This is normal operation mode. The controller operates the respective 

feeders to automatically maintain the parameters set for both pH and ORP. 
 

3.3.3 pH SET mode:

 This enables the six programming buttons to set desired pH parameters.  

 
Note: When scrolling through the set modes, to reverse the direction simply release the 
button momentarily and press the button again. 
 

Feed Once button

:  By pressing the FEED ONCE button, the pH feeder will feed and delay 

for one complete feed cycle.  See FEED TIME Button for feed/delay times. If the Feed time 
is set for “Continuous feed” the manual feed will not operate. 

 

Set Level button

:  Pressing the SET LEVEL button once will display the current set level. To 

change the set level, press and hold the SET LEVEL button (which displays in 0.1 pH 
increments) until the desired level is reached. 

 

Feed Time

: The feed times are displayed in seconds.  

    Each feed cycle includes a five (5) minute delay time. Pressing the FEED TIME button 

allows the user to scroll through the available feed times. Release the button when the 
desired pH feed time is reached. To set the controller in Continuous feed, release the 
button when the display reads “con”. Continuous feed runs feeder continuously; (1) until set 
point is reached or (2) until Consecutive Feed Alert Limit is reached or (3) until Hi/Low Alert 
limit is reached. See appendix for Consecutive Feed Alert Limit details. Feed time can also 
be set to “off”. 

 
Note: The controller will overshoot the pH Set Level by 0.1 to reduce on/off cycles. 
 

Содержание 554000

Страница 1: ...MODE FEED ONCE pH AUTO ORP LEVEL SET pH FEED ALERT CALIB pH FEED TIME HI ORP LOW ORP FEED L O W ALERT pH Operating Manual MODELS RC554XP AND 554000 ORP pH Digital Controller IMPORTANT SAFETY INSTRUCT...

Страница 2: ...lso remove power from the controller Provide a properly located outlet controlled by the circulating pump circuit 1 6 WARNING Risk of electric shock pinching chemical exposure Remove power sources or...

Страница 3: ...allation 4 1 Locating the controller 12 4 2 Mechanical installation 12 4 3 Power panel access 13 4 3 1 Dip switches 13 4 3 2 Fuses 13 4 3 3 Flow switch 13 4 3 4 Globe Flowcell 14 5 Operation 5 1 Start...

Страница 4: ...ings Press and release the MODE button until the desired ORP or pH LED is lit Once the settings are changed they will remain at those settings until they are changed again Set level press the SET LEVE...

Страница 5: ...isplay resolution The ORP set point is adjustable from 400 to 900 mV with default set point of 650 mV During an ORP feed cycle the ORP feed lamp will flash when sanitizer chemicals are being fed and i...

Страница 6: ...nternal terminal strip is provided for field wiring of the controller The internal step down transformer has a class two energy limiting rating to provide for electrical safety Note When automating an...

Страница 7: ...s Terminal strip for hardwire applications included Displays ORP and pH red digital Power and flow indicator LED Alert indicator Feed indicator LED ORP pH Mode indicator LED pH ORP Auto Note feed lamp...

Страница 8: ...onitors pH and ORP and displays programmed set points The Digital Display numbers will flash if Consecutive Feed Alert Limit is exceeded 5 pH STANDBY LAMP AND PROGRAMMING BUTTONS When pH standby lamp...

Страница 9: ...set desired pH parameters Note When scrolling through the set modes to reverse the direction simply release the button momentarily and press the button again Feed Once button By pressing the FEED ONCE...

Страница 10: ...calibration allows the adjustment of 1 pH in 1 pH increments Consecutive Feed Alert Limit The Digital Display numbers will flash and the pump feeder will not activate if the Set Level is not reached...

Страница 11: ...sed the ORP readout will scroll through the available ORP levels 100 mV to 640 mV in 5 mV increments and OFF Release the button when the desired level is reached The pH CALIB button is not functional...

Страница 12: ...oller in a location accessible to the public Install the controller in an area protected from natural elements sun rain freezing etc See appendix for typical feed system schematics 4 2 Mechanical Inst...

Страница 13: ...These fuses are located inside the lower panel The fuse holders are shipped with 5 amp fuses Replacement fuses are 5mm x 20mm Fast Acting IEC 4 3 3 Flow Switch The controller has a flow switch termina...

Страница 14: ...perate as a power light It is recommended the jumper be retained to assist in troubleshooting if necessary 4 3 4 Globe Flowcell see Globe Flowcell Operating Manual Connect the Globe Flowcell grounding...

Страница 15: ...ion in Appendix for Dip switch settings To verify that acid feed mode is selected adjust the pH set level below the pH indicated on the display The feed lamp should come on if the controller is in aci...

Страница 16: ...down in small increments for example 10mV to 25 mV increments to lock in the desired sanitizer level Note The ORP reading is highly dependent on both the pH and the cyanuric acid levels Both of these...

Страница 17: ...eed time is 0 6 sec on with 5 minute delay Feeders may require longer feed time If time is too short set points will not be maintained If feed time is too long overfeeding chemicals may occur Correct...

Страница 18: ...o turn the controller On and return to operating mode The last two steps are extremely important because this puts the controller back in operating mode If these two steps are not performed the contro...

Страница 19: ...switch flow cell valves feeders tubing etc are not covered under this warranty Heavy duty probes are warranted from the date of original purchase for one 1 year ROLA CHEM under no circumstances shall...

Страница 20: ...in the timed feed mode 1 Turn off remove power then move 2 dip switch to ON 2 Re power press MODE to set it for ORP or pH 3 Note feed time setting then Set FEED TIME to OFF 4 Press FEED ONCE button t...

Страница 21: ...s now in test mode Test mode reduces the feed delay time from 5 minutes to 5 seconds to simplify diagnostics E Turn the controller Off again to exit test mode F Turn the controller On to return to ope...

Страница 22: ...ROLA CHEM Digital Controller PN 554135 12 26 18 Page 22 of 24 8 4 Typical System Installations...

Страница 23: ...ROLA CHEM Digital Controller PN 554135 12 26 18 Page 23 of 24 8 4 Typical System Installations cont...

Страница 24: ...ROLA CHEM Digital Controller PN 554135 12 26 18 Page 24 of 24 NOTES...

Отзывы: