ROLA-CHEM Digital Controller                                        PN 554135      12/26/18                                               Page: 19 of 24 

7. Warranty and Service    

        
Limited Warranty: 
 

ROLA-CHEM warrants the original purchaser that this unit is free from manufacturing 
defects in material and workmanship from the date of the original purchase for five (5) years. 
  
If this unit fails within the five (5) year period it will be repaired or replaced (ROLA-CHEM’s 
option) at no charge when returned to ROLA-CHEM with proof of purchase receipt. This 
warranty does not apply to any product damage caused by improper use, accident, misuse, 
improper line voltage, fire, flood, lightning, earthquake, other acts of nature, or if product was 
altered or opened by anyone other than qualified ROLA-CHEM personnel.  
 
Effective date for this limited warranty – January 1st, 2019. 

 
All expendable items (probes, flow switch, flow cell, valves, feeders, tubing, etc.) are not 
covered under this warranty. 
 
Heavy duty probes are warranted from the date of original purchase for one (1) year. 
 
ROLA-CHEM under no circumstances shall be liable for any consequential damages directly 
or indirectly caused by this unit. Please observe all rules and regulations required by state 
and local regulations, building codes, health codes, OSHA, etc. 
 

Service Procedure:

  For operation assistance in the United States please call: 

(800) 549-4473 and ask for Customer Service, Monday through Friday 8:00 am-5:00 pm 
Central Time or email: [email protected]. Have model number and serial number 
available. 
 
ROLA-CHEM has specialized knowledge and equipment to test and diagnose your product. 
Contact our service personnel as noted above for assistance. If you are directed to ship the 
product to ROLA-CHEM and given an RGA#, please note RGA# on the package and ship 
freight pre-paid to: 
 

 

 

ROLA-CHEM 

5858 Centerville Road 

St. Paul, MN 55127-6804 

 
 
 
 

www.rola-chem.com 

 

 

Содержание 554000

Страница 1: ...MODE FEED ONCE pH AUTO ORP LEVEL SET pH FEED ALERT CALIB pH FEED TIME HI ORP LOW ORP FEED L O W ALERT pH Operating Manual MODELS RC554XP AND 554000 ORP pH Digital Controller IMPORTANT SAFETY INSTRUCT...

Страница 2: ...lso remove power from the controller Provide a properly located outlet controlled by the circulating pump circuit 1 6 WARNING Risk of electric shock pinching chemical exposure Remove power sources or...

Страница 3: ...allation 4 1 Locating the controller 12 4 2 Mechanical installation 12 4 3 Power panel access 13 4 3 1 Dip switches 13 4 3 2 Fuses 13 4 3 3 Flow switch 13 4 3 4 Globe Flowcell 14 5 Operation 5 1 Start...

Страница 4: ...ings Press and release the MODE button until the desired ORP or pH LED is lit Once the settings are changed they will remain at those settings until they are changed again Set level press the SET LEVE...

Страница 5: ...isplay resolution The ORP set point is adjustable from 400 to 900 mV with default set point of 650 mV During an ORP feed cycle the ORP feed lamp will flash when sanitizer chemicals are being fed and i...

Страница 6: ...nternal terminal strip is provided for field wiring of the controller The internal step down transformer has a class two energy limiting rating to provide for electrical safety Note When automating an...

Страница 7: ...s Terminal strip for hardwire applications included Displays ORP and pH red digital Power and flow indicator LED Alert indicator Feed indicator LED ORP pH Mode indicator LED pH ORP Auto Note feed lamp...

Страница 8: ...onitors pH and ORP and displays programmed set points The Digital Display numbers will flash if Consecutive Feed Alert Limit is exceeded 5 pH STANDBY LAMP AND PROGRAMMING BUTTONS When pH standby lamp...

Страница 9: ...set desired pH parameters Note When scrolling through the set modes to reverse the direction simply release the button momentarily and press the button again Feed Once button By pressing the FEED ONCE...

Страница 10: ...calibration allows the adjustment of 1 pH in 1 pH increments Consecutive Feed Alert Limit The Digital Display numbers will flash and the pump feeder will not activate if the Set Level is not reached...

Страница 11: ...sed the ORP readout will scroll through the available ORP levels 100 mV to 640 mV in 5 mV increments and OFF Release the button when the desired level is reached The pH CALIB button is not functional...

Страница 12: ...oller in a location accessible to the public Install the controller in an area protected from natural elements sun rain freezing etc See appendix for typical feed system schematics 4 2 Mechanical Inst...

Страница 13: ...These fuses are located inside the lower panel The fuse holders are shipped with 5 amp fuses Replacement fuses are 5mm x 20mm Fast Acting IEC 4 3 3 Flow Switch The controller has a flow switch termina...

Страница 14: ...perate as a power light It is recommended the jumper be retained to assist in troubleshooting if necessary 4 3 4 Globe Flowcell see Globe Flowcell Operating Manual Connect the Globe Flowcell grounding...

Страница 15: ...ion in Appendix for Dip switch settings To verify that acid feed mode is selected adjust the pH set level below the pH indicated on the display The feed lamp should come on if the controller is in aci...

Страница 16: ...down in small increments for example 10mV to 25 mV increments to lock in the desired sanitizer level Note The ORP reading is highly dependent on both the pH and the cyanuric acid levels Both of these...

Страница 17: ...eed time is 0 6 sec on with 5 minute delay Feeders may require longer feed time If time is too short set points will not be maintained If feed time is too long overfeeding chemicals may occur Correct...

Страница 18: ...o turn the controller On and return to operating mode The last two steps are extremely important because this puts the controller back in operating mode If these two steps are not performed the contro...

Страница 19: ...switch flow cell valves feeders tubing etc are not covered under this warranty Heavy duty probes are warranted from the date of original purchase for one 1 year ROLA CHEM under no circumstances shall...

Страница 20: ...in the timed feed mode 1 Turn off remove power then move 2 dip switch to ON 2 Re power press MODE to set it for ORP or pH 3 Note feed time setting then Set FEED TIME to OFF 4 Press FEED ONCE button t...

Страница 21: ...s now in test mode Test mode reduces the feed delay time from 5 minutes to 5 seconds to simplify diagnostics E Turn the controller Off again to exit test mode F Turn the controller On to return to ope...

Страница 22: ...ROLA CHEM Digital Controller PN 554135 12 26 18 Page 22 of 24 8 4 Typical System Installations...

Страница 23: ...ROLA CHEM Digital Controller PN 554135 12 26 18 Page 23 of 24 8 4 Typical System Installations cont...

Страница 24: ...ROLA CHEM Digital Controller PN 554135 12 26 18 Page 24 of 24 NOTES...

Отзывы: