BrightSign Compact
This information applies to a product under development. Its characteristics and specifications are subject to change without notice. Roku assumes no
obligation regarding future manufacturing unless otherwise agreed to in writing.
www.rokulabs.com
© Roku 2008
Appendix A
Flow Chart: (for Repair Center Use)
(1) Power Start
Check U17,
L3, C204
Check D12 & D33
for shorts
Is the Voltage of
L2 = 5V
?
Is the Voltage of
TP16
3.3V?
No
No
Yes
Yes
No LEDs
on
Is the Output power
adapter 5V DC
?
Replace Power
Adapter
No
Check U33,
Reset circuit U36,
R76, D5