28
Each system has only one Administrator Code; user cannot change
Master Code with it, but owns the other same rights as Master Code.
System can set 1-6 six User Codes. User can arm/disarm the system
with User Code, but cannot change system settings and check system
status.
System has one this code, with which user can only arm the system,
cannot disarm the system or do other operations.
System has a one-off code, which can disarm the system one time, and
then it will be invalid.
System is designed with Duress Arm. If user is forced to disarm the
system, just comply with the intruder's wishes to disarm the system
but use Duress Code, so system can send a silent duress alarm to the
Central Monitor Station simultaneously.
All codes used for disarming are called disarm code. The disarm code
added 1 to the last digit would become Duress Code. Duress Code and
the disarm code share the first 3 digits. For example:
User code =1-2-3-4; duress code is 1-2-3-5
User code =6-7-8-9; duress code is 6-7-8-0
●User Code
●Code for Arm Only
●One-off Code
Duress Code
●
Note: Under no circumstances the Duress Code is used haphazardly or without
reason. Central Monitor Stations, along with Police Departments, treat Duress
Codes very seriously and take action immediately.
i
Wireless Alarm System