5
GENEVA
UNVENTED WATER HEATER
WARNING:
Do not install the product directly below a fixed socket outlet or
connection box. Do not install or use outdoors. Do not install directly underneath a
shelf. This product is designed for internal wall-mounted installation using the ROINTE
template, installation kit and fixing items provided.
3.4. Location and positioning
The unit is designed to be vertically wall mounted, indoors, in a frost-free environment.
When choosing a suitable location for the cylinder, consideration should be given to the
routing of the discharge pipe to a convenient point and also the availability of an adequate
power supply for connecting the sheathed heating elements.
The wall onto which the product is mounted must be of good sound masonry construction
capable of holding the weight of the cylinder when full of water (see section 11 “Technical
Specifications” for weights).
The position of the cylinder should provide easy
access for servicing and replacing the sheathed
heating elements and magnesium anodes should
the need arise.
Pipe runs should be made as short as possible and
lagged to prevent heat loss.
To allow for servicing and repairs, the cylinder must
be mounted at least 500 mm above any object or
surface, so that access is available to the electric
connectors and the heating elements (if necessary)
may be removed (see figure opposite).
Never install the horizontal product with the wall
brackets on the floor or horizontal plane.
Please do not cover the products or place any
object (including furniture) directly in front of it.
We recommend this product is mounted close to an external wall so that the discharge
pipe can be routed to a safe, visible place.
The tundish should be mounted in a visible location so that it can be easily inspected.
WARNING:
The product is IP22 rated, therefore must not be installed in bathrooms or
where itself or the control panel is within the reach of persons in water.