10
· Switch off power to the appliance- if the model is fitted with a cord and a plug – unplug it from the socket.
For the other models – switch off the shut-down device built into the wiring of the appliance (see item 3.1 and
item 3.2 from section VI)
· To fill the appliance with water – open the tap until a steady jet of water starts running, not interrupted by
air from the water system
· Switch on the power to the appliance again
Do not use the appliance before you have made sure that it is full of water!
When water runs or supply is interrupted, it is usual to hear a sound from the switching over of the automatic
device for switching on and off of the electrical heater.
Specific features of the various models:
6.2. Models for the kitchen.
The heater of the appliance switches on automatically when you run water from the red-coloured handle of
the mixing tap. You can control the temperature of the outgoing water by regulating the water jet from the
same handle. By increasing the water jet you lower the temperature; when decreasing the jet the temperature
goes up. The heater switches off automatically when water from the red-coloured tap stops running.
When you wish to use only cold water, use the blue-coloured tap.
RECOMMENDATION! Control the temperature of the hot water only by changing the water flow rate by using
the red-coloured tap. Do not mix hot and cold water.
It is possible that a little water leaks out of the outlet of the spout after shutting the mixing tap. This is not
a fault but is caused by the emptying of the leading-out pipe of the water tank because the appliance has a
constantly open to the atmosphere outlet.
Do not over-tighten the taps to their end position to avoid damaging them!
Never block the S-spout and never shut the outlet of the mixing tap. Regularly remove the scale from it.
6.3. Model for the bathroom.
The heater is automatically switched on when water runs from the tap at the inlet of the appliance. Increase
the flow in order to lower the temperature of the hot water; to increase the temperature, decrease the water
flow.
The heater switches off automatically when water flow through the appliance stops running.
Regularly remove limestone from the shower head.
These models have inbuilt device to protect from high temperatures of the outgoing water. It can be activated
when the water flow through the appliance is low. In that case the temperature lowers abruptly. After a while
the device restores its function and the temperature goes up. Thus you have alternation of hot and cold jets
in close succession. Such a mode is not recommended and has to be avoided. You have to increase the water
flow until constant temperature of the outgoing water is achieved.
6.4. IN LINE models
Their heater is automatically switched on when water runs through the appliance. Increase the flow in order
to lower the temperature of the hot water. In order to increase the temperature, decrease the water flow.
RECOMMENDATION! Control the temperature only by changing the water flow rate. Do not mix hot and cold
water.
Содержание Capri CWI350DHWK4