22
10. ERP DIRECTIVE (EU) 2015/1188
ITEM
SYMBOL
UNIT
0330RAD
0550RAD
0770RAD
0990RAD
1210RAD
1430RAD
1600RAD
HEA
T OUTPUT
Nominal heat output
P
nom
kW
0.33
0.55
0.77
0.99
1.21
1.43
1.6
Minimal heat output
P
min
kW
n/a
n/a
n/a
n/a
n/a
n/a
n/a
Maximum continuous heat output
P
max,c
kW
0.33
0.55
0.77
0.99
1.21
1.43
1.6
AUXILIAR
Y ELECTRICITY CONSUMPTION
At nominal heat output
el
MAX
kW
0.33
0.55
0.77
0.99
1.21
1.43
1.6
At minimum heat output
el
MIN
kW
0.33
0.55
0.77
0.99
1.21
1.43
1.6
In standby mode
el
SB
kW
0.002
0.002
0.002
0.002
0.002
0.002
0.002
TYPE OF HEA
T OUTPUT/ROOM TEMPERA
TURE CONTROL (SELECT ONE)
Single-level heat output, no inter
nal temperatur
e contr
ol
—
—
—
—
—
—
—
—
—
Two or mor
e manual levels, without inter
nal temperatur
e contr
ol
—
—
—
—
—
—
—
—
—
Inter
nal temperatur
e contr
ol by mechanical thermostat
—
—
—
—
—
—
—
—
—
With electr
onic interior temperatur
e contr
ol
—
—
—
—
—
—
—
—
—
Electr
onic indoor temperatur
e contr
ol and daily timer
—
—
—
—
—
—
—
—
—
Electr
onic indoor temperatur
e contr
ol and weekly timer
—
—
OTHER CONTROL OPTIONS (MUL
TIPLE SELECTIONS POSSIBLE)
Interior temperatur
e contr
ol with pr
esence detection
—
—
—
—
—
—
—
—
—
Interior temperatur
e contr
ol with detection of open windows
—
—
With r
emote contr
ol / distance option
—
—
With adaptive start-up contr
ol
—
—
With operating time limitation
—
—
With black lamp sensor
—
—
—
—
—
SEASONAL SP
ACE HEA
TING ENERGY EFFICIENCY
n s
—
39.0%
39.0%
39.0%
39.0%
39.0%
39.0%
39.0%