5
water (marked with a blue ring) and hot water discharge (marked with a red ring). The interior of the tank
is made of steel, treated against corrosion by a special glass-ceramic coating.
2. The flange is equipped with an electrical resistance and magnesium anode. The flange is fixed in the
water tank with bolts.
The electric resistance heats the water in the tank and is controlled by the thermostat, which automatically
maintains the programmed temperature.
The plastic control panel incorporates: the ignition switch (depending on the model), adjustable thermostat
(depending on the model) and control lights. For thermal protection, a device is incorporated that disconnects
the water heater from the power supply when the water temperature reaches excessive values. If the device
is activated, you must call the Rointe Technical Service. The control lights (depending on the model) indicate
the current mode of the unity.
The return safety valve prevents complete emptying of the appliance in case of cold water supply interruption.
The valve protects the device from pressure increases above the allowed value during heating, releasing excess
pressure through the drain outlet. The water that drips through the drain during the heating process does not
indicate any problem. This is a normal occurrence.
IMPORTANT: The protection valve cannot guarantee the protection of the water heater when the water supply
is produced at a higher pressure than that determined for the water heater.
4. INSTALLATION
4.1. Installation
We recommend that the water heater is installed in the vicinity where hot water is required, in order to
reduce heat loss. The selected location should exclude the
possibility of splashing water from the shower or other
contacts with water. The appliance should be installed
on a wall by means of mounting brackets. Two screws
are used to fix the device (minimum Ø 6 mm) firmly on
the wall. These are included in the mounting kit. The
installation templates either above or below the stack are
universal and allow the space between the bolts to vary
between 96 and 114mm.m.
IMPORTANT: The water heater models suitable to be installed below/above the battery are indicated on the water
heater. The water heater suitable for the installation below the stack are mounted in such a way that the outlet/
inlet of the pipes are pointed downwards (towards the floor). The water heater suitable for the installation on the
stack are mounted in such a way that the outlet/inlet of the pipes are pointed upwards (towards the ceiling).
ATTENTION:
In order to avoid injury to the user and/or third parties in case of faults in the hot water supply
system, the appliance must be installed in facilities equipped with waterproof flooring. Do not place objects
that are not waterproof under the device under any circumstances.
min 96 mm
max 114 mm
8 mm
Содержание 8436045913159
Страница 1: ...Compact digital electric D W H heater INSTRUCTION INSTALLATION GUIDE Venice ...
Страница 2: ...2 ...
Страница 16: ...16 ...
Страница 17: ...17 NOTES ...
Страница 18: ...18 NOTES ...
Страница 19: ...19 ...