Thermostats 

AM1-WA1

 and 

AM1-XA1

 

automatically performs ON/OFF fan control in 
accordance with the temperature fluctuation inside 
the equipment. It helps improve the equipment’s 
“environmental” performance relative to energy 
savings, noise reduction, etc.

List of safety standard approved products (Model, Standards, File No., Certification Body) 

 

 Page G-11

Features

 

Effective for Energy-Saving

 

Thermostat makes it possible for fans to operate only when cooling 
is necessary.
This product makes for energy-saving by automatically stopping fans 
for example, at night, when the amount of heat generation declines 
following the load rate’s decline in equipment, or in winter, when the 
ambient temperature drops and forced cooling is not necessary.

Noise Reduction

 

The fans are operated only when cooling is required, thereby keeping 
fan noise to a minimum.

 

 RoHS-Compliant

Thermostats 

AM1-WA1

 and 

AM1-XA1

 conform to the RoHS 

Directive that prohibits the use of six chemical substances including 
lead and cadmium.

Details of RoHS Directive 

 

 Page G-38

Easy Setting

 

Range of operating temperature: 0 to 

+

60˚C (

+

32 to 

+

140˚F)

In addition, the setting is very easy; all you have to do is set the front 
dial to the desired temperature.

Elimination of Power Supply

 

There is no need to provide a separate power supply for the 
thermostat.

Conforms to DIN Rail, Compact Design

 

W33 mm

×

H60 mm

×

D35 mm (W1.30 in.

×

H2.36 in.

×

D1.38 in.)

Thermo bimetal built-in thermostat

Product Line

 

Type

Model

Fahrenheit

AM1-WA1

Centigrade

AM1-XA1

Thermostat, Operating Manual

The following items are included in each product.

Specifications 

 

 

Item

Specifications

Type of Sensor

Thermo bimetal, Contact: Normal open

Operating Temperature Range

[0

60

˚C

 (

+

32

140

˚

F)]

±

10

˚C

 (18

˚

F)

Differential

[Operating temperature 

7

˚C

 (12.6

˚

F)]

±

4

˚C

 (7.2

˚

F)

Applicable Lead Wire Size

AWG18

14 (0.75

2.5 mm

2

)

General Specifications

 

Item

Specifications

Dielectric 
Strength

Between the frame 
and the terminal

Sufficient to withstand 3.75 kVAC for one minute under 
normal ambient temperature and humidity.

Between the 
terminals

Sufficient to withstand 0.5 kVAC for one minute under 
normal ambient temperature and humidity.

Ambient Temperature

20

∼+

80

˚C

 (

4

∼+

176

˚

F)

Ambient Humidity

90 % or less (non-condensing)

Color

Light gray

Notes:

If foreign objects get into the sensor, the thermostat may not work properly. The use of a filter 

 

at the intake is recommended so foreign objects will not enter the area where the sensor is 
located.
Be sure to use the applicable products.

 

Install the product on an IEC (DIN) rail. Make sure that no force (tension, stress, etc.) is 

 

applied to the terminal section.

Thermostats

AM1-WA1/AM1-XA1

 RoHS-Compliant

AM1-WA1

AM1-XA1

Содержание AM1-WA1

Страница 1: ...le Flow MRS AC Input MU DC Input Long Life MDE DC Input MDS MD AC Input MB DC Input MBD AC Input MF DC Input MFD Thermostats Accessories Installation Cooling Module Axial Flow Fans Centrifugal Blowers Cross Flow Fans E 133 Cooling Fans Thermostats Thermostats ...

Страница 2: ...asy all you have to do is set the front dial to the desired temperature Elimination of Power Supply There is no need to provide a separate power supply for the thermostat Conforms to DIN Rail Compact Design W33 mm H60 mm D35 mm W1 30 in H2 36 in D1 38 in Thermo bimetal built in thermostat Product Line Type Model Fahrenheit AM1 WA1 Centigrade AM1 XA1 Thermostat Operating Manual The following items ...

Страница 3: ...than one fan is needed to produce the required air flow or static pressure For example a thermostat can control a maximum of nine MU1238 type fans A six fan configuration is shown Application Example MU1238 AM1 WA1 AM1 XA1 Connection Example AC Power Supply AM1 WA1 AM1 XA1 When using 6 fans MU1238 Thermostat Number of Fans Input W Noise Level dB A ON 6 84 51 OFF 0 0 Applicable Products Input Serie...

Страница 4: ...ature Operation Operation Max Load of System 40 C 104 F 33 C 91 F 25 C 77 F 18 C 64 F Lower No Operation Notes Connect the lead wire to the thermostat as shown in the diagrams regardless of how many fans are used or of the fan s wire diameter When connecting multiple fans always use a terminal block Don t connect the lead wires of multiple fans directly to the thermostat When using variable flow f...

Отзывы: